Operating the Drive
6-12
AC890PX AC Drive
Forced Coast Stop
Using the Not Coast Stop mode immediately disables the power stack, causing the load to coast to a stop.
The drive gives priority to the NOT COAST STOP signal. The NOT FAST STOP signal is therefore ignored while NOT
COAST STOP is active.
POWER CIRCUIT DISABLED
SPEED DEMAND
REMOTE SETPOINT
Speed 0%
SPEED TRIM
NOT COAST STOP
Figure 3.8
Forced Coast Stop example