SETPOINT
PREF: 103.01
Default: 10.00 %
Range: -100.00 to 100.00 %
The setpoint is the target reference that the Drive will ramp to.
ACCEL TIME
PREF: 103.02
Default: 1.0 s
Range: 0.0 to 3000.0 s
The time that the Drive will take to ramp the jog setpoint from 0.00% to 100.00%.
DECEL TIME
PREF: 103.03
Default: 1.0 s
Range: 0.0 to 3000.0 s
The time that the Drive will take to ramp the jog setpoint from 100.00% to 0.00%.
Functional Description
The REFERENCE JOG function block is used to configure the action of the Drive when used in jog mode. The various
operating modes are described in more detail in Chapter 4 or 5: - The Start/Stop Mode Explained.