Programming
D-258
AC890PX AC Drive
Product Related Default Values
The Default values in the tables below are correct for when a 2.2kW Frame B power board is fitted.
* Frequency Dependent Defaults
These parameter values (marked with “*” in function block descriptions) are dependent upon the drive’s
default motor BASE FREQUENCY.
Parameter
Function Block
PREF
Default
50Hz Operation 60Hz Operation
BASE FREQUENCY
MOTOR INDUCTION 27.03
50.0Hz
60.0Hz
MOTOR CONNECTION MOTOR INDUCTION 27.08
STAR
STAR
MOTOR VOLTAGE
MOTOR INDUCTION 27.04
*
*
NAMEPLATE RPM
MOTOR INDUCTION 27.07
1420 RPM
1750 RPM
MAX SPEED
REFERENCE
101.08 1500 RPM
1800 RPM
230V, 400V or 500V depending upon the power build of the unit - refer to the Model Number on
the Product Label.