D-177
Programming
AC890PX AC Drive
The DISABLED WORD 4, ACTIVE WORD 4 and WARNINGS WORD 4 parameters use a four digit hexadecimal number to
identify individual trips. Each trip has a unique corresponding number as shown below.
Trip Name (MMI)
First Trip Value
Mask EXT 1+
User Disable
Auto-restart
OUTPUT GBX ERROR
49
0x0001
Yes
N/A
APP HALTED
50
0x0002
N/A
N/A
APP ERROR
51
0x0004
N/A
N/A
FIRMWARE ERROR
52
0x0008
N/A
N/A
TRIP 53 (Reserved)
53
0x0010
N/A
N/A
TRIP 54 (Reserved)
54
0x0020
N/A
N/A
TRIP 55 (Reserved)
55
0x0040
N/A
N/A
TRIP 56 (Reserved)
56
0x0080
N/A
N/A
RESOLVER ERROR
57
0x0100
N/A
N/A
I2T MOTOR TRIP
58
0x0200
N/A
N/A
TRIP 59 (Reserved)
59
0x0400
N/A
N/A
SAFE TORQUE OFF
60
0x0800
N/A
N/A
REF ENCODER CAL
61
0x1000
YES
N/A
REF ENCODER FAIL
62
0x2000
YES
N/A
DRIVE CONFIG ERR
63
0x4000
N/A
N/A
TRIP 64 (Not Affected)
64
0x8000
N/A
N/A