![Parker AC890PX Series Product Manual Download Page 324](http://html1.mh-extra.com/html/parker/ac890px-series/ac890px-series_product-manual_755704324.webp)
Programming
D-84
AC890PX AC Drive
Parameter Descriptions
MAX VOLTAGE
PREF: 134.05
Default: 400.00
Range: 20.00 to 640.00 V
Set the motor’s maximum ac input voltage (in Volts rms).
THERM PROTECTION
PREF: 134.06
Default: FALSE
Range: FALSE / TRUE
Motor’s thermal protection feature.
●
MAX SPEED
PREF: 134.07
Default: 4300
Range: 0 to INT MAX
Set the motor’s maximum mechanical speed (in rpm)
●
MAX CURRENT
PREF: 134.08
Default: 10.60
Range: 0.00 to 4096.00 A
Set the motor’s maximum rms current. This parameter is used to limit the current demand
●
PERM CURRENT
PREF: 134.09
Default: 4.90
Range: 0.00 to 4096.00 A
Set the motor’s permanent rms current. Permanent current at low speed (in Amp rms) or nominal current.
Refer to MOTOR CURRENT % in the FEEDBACKS function block. A value of 100% = PERM CURRENT.
●
PERM TORQUE
PREF: 134.10
Default: 6.40
Range: 0.00 to 30000.00 Nm
Set the motor’s permanent torque.
Refer to TORQUE FEEDBACK in the FEEDBACKS function block. A value of 100% = PERM TORQUE.
LOW SPEED VALUE
PREF: 134.11
Default: 0
Range: 0 to INT MAX rpm
Set the motor’s low speed value (in rpm) below which the current must be reduced.
If this parameter is unknown, value must be set to 0 rpm.
●
POLES
PREF: 134.12
Default: 10
Range: 0 to 400
Set the number of motor poles, e.g. for a 4 pole motor enter "4".
Summary of Contents for AC890PX Series
Page 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Page 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Page 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Page 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Page 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...