Keypad Menus
8-17
AC890PX AC Drive
QUICK SETUP MENU
PREF
6911 Display
Description
Range
Default
27.04
* ** MOTOR VOLTAGE
This parameter contains the motor nameplate voltage
at base frequency
0.0 to 575.0V
product
code
dependent
27.07
* ** NAMEPLATE RPM
This parameter contains the motor nameplate full-
load rated speed. This is the motor speed in rpm at
base frequency minus full load slip
0.0 to 30000.0 RPM
product
code
dependent
27.09
MOTOR POLES
This parameter contains the number of motor poles,
as supplied on the motor nameplate
0=2 pole
1=4 pole
2=6 pole
3=8 pole
4=10 pole
5=12 pole
1
27.08
* ** MOTOR
CONNECTION
This parameter contains the motor nameplate
connection.
0= DELTA
1= STAR
1
71.01
PULSE ENC VOLTS
The voltage output from the encoder feedback card.
10 to 20V
5.0
71.02
ENCODER LINES
The number of lines must be set to match the type of
encoder being used. Incorrect setting of this
parameter will result in an erroneous speed
measurement.
250 to 32767
2048
71.03
ENCODER INVERT
When TRUE, changes the sign of the measured speed
and the direction of the position count.
0=FALSE
1=TRUE
0
80.01
AUTOTUNE ENABLE
Determines whether the Autotune sequence is
operational or not. The Autotune sequence is
operational when set to TRUE and the drive is run
0=FALSE
1=TRUE
0
Summary of Contents for AC890PX Series
Page 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Page 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Page 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Page 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Page 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...