Alert Message IDs
ID
Message
Reason
43
SUPER USER
TRUE
Reserved for Parker Hannifin Manufacturing.
44
INCOMPATIBLE
POWER BOARD
Power board 500v and/or underlap signals incompatible with selected product code.
45
CALIBRATION
CHECKSUM FAIL
The control board calibration data is invalid.
46
INCOMPATIBLE
PCB
Software is not compatible with this version of control card PCB.
47
INCOMPATIBLE
POWER BOARD TYPE
Stack has been marked as a 650 or Baldor stack
48
INCOMPATIBLE
EEPROM FLAGS
Reserved flags in stack eeprom are not zero. See comms command "ri".
49
INCOMPATIBLE
POWER BOARD CODE
Product code not compatible with this version of software.
50
KEY INACTIVE
Alert shown when the RUN key is pressed when the Pre-charge relay is still open. This
implies that the DC Link voltage is below the under-voltage trip level.
51
INCOMPATIBLE STO
TEST RECORD
The internal record confirming that the STO feature is tested has become corrupted.
52
LOCKED STO TEST
RECORD
The control card is incompatible with the power stack STO feature.