Operating the Drive
6-10
AC890PX AC Drive
Coast to Stop
Set the SETUP::SEQ & REF::REFERENCE STOP::RUN STOP MODE parameter to COAST.
In this mode the DECEL TIME ramp and the STOP TIME ramp are both ignored. Thus the SPEED DEMAND changes
immediately to 0% as soon as the Stop command is given. The power stack is also immediately disabled at this time, causing
the load to coast.
POWER CIRCUIT DISABLED
SPEED DEMAND
REMOTE SETPOINT
Speed 0%
RUN input
Figure 3.6
Coast to Stop with a Remote Reference