Programming
D-170
AC890PX AC Drive
Parameter Descriptions
TRIP 8
PREF: 96.08
Default: 0
Range: As above
Records the eighth most recent trip that caused the Drive to stop.
TRIP 9
PREF: 96.09
Default: 0
Range: As above
Records the ninth most recent trip that caused the Drive to stop.
TRIP 10 (OLDEST)
PREF: 96.10
Default: 0
Range: As above
Records the tenth most recent trip that caused the Drive to stop.
Functional Description
This function block provides a view of the ten most recent trips that caused the Drive to stop. Every time a new trip occurs this
is entered as TRIP 1 (NEWEST) and the other recorded trips are moved down. If more than ten trips have occurred since the
drive was configured then only the ten most recent trips will be available for inspection.
These parameters are preserved through a power failure.