Programming
D-106
AC890PX AC Drive
Parameter Descriptions
POSITION
PREF: 120.05
Default: 0.0000
Range: 0.0000 to 1.0000
The absolute position demand (1.0 = 1 load mechanical revolution).
VELOCITY
PREF: 120.06
Default: 1.00 %
Range: 0.10 to 300.00 %
This parameter defines the maximum velocity of the move, set in percent of maximum load speed.
ACCELERATION
PREF: 120.07
Default: 1.00 %
Range: 0.01 to 3000.00 %
This parameter defines the maximum acceleration of the move, set in percent of maximum load speed per second.
ABS POSITION
PREF: 120.08
Default: —.xxxx
Range: —.xxxx
This diagnostic displays the absolute position feedback (1.0 = 1 load mechanical revolution).
ACTIVE
PREF: 120.10
Default: FALSE
Range: FALSE / TRUE
This diagnostic is TRUE to indicate Move Abs is active (i.e. the position demand is being provided by this block)
DONE
PREF: 120.11
Default: FALSE
Range: FALSE / TRUE
This diagnostic is TRUE to indicate the last Move Abs enabled has completed.
STATE
PREF: 120.12
Default: 1
Range: See below
This diagnostic indicates the state of the Move Abs move.
Enumerated Value
:
State
0 : RESET
the move to master is in a reset state and cannot be used.
1 : READY
the move Abs is ready to be enabled
2 : POS AQUIRE the target position for the move is being acquired
3 : ALIGN
the move is active
4 : DONE
the move Abs is complete
Summary of Contents for AC890PX Series
Page 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Page 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Page 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Page 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Page 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...