Related Programming
• FF1 (System): SMDR Print
• FF1 (System): Parity Check
• FF1 (System): Odd/Even Parity
• FF1 (System): Baud Rate
• FF1 (System): Stop Bit Length
• FF1 (System): Data Length
• FF1 (System): Serial Port Flow Control (X On/ X Off)
• FF1 (System): SMDR Display Start Timer for CO Calls
• FF1 (System): SMDR Printing Mode 1: Outbound, Inbound, Network
• FF1 (System): SMDR Printing Mode 2: Long Distance and Local Calls
• FF1 (System): SMDR Printing Mode 3: Header Title
• FF3 (Extension) Station Message Detail Recorder (SMDR) Report
Hardware Requirements
• A printer or external call accounting system is required to receive SMDR
data.
Considerations
• Unlike other CPC circuit cards, the CPC-EX supports two serial ports.
Serial Port 1 is labeled
CN4
and is located on the backplane. Serial Port 2
is labeled
CN5
and is located on the front of the CPC-EX card. Serial Port
2 requires a special interface cable.
• Be sure to select the correct port to output SMDR data. From the
Attendant’s phone:
-
dial
#90
to set Serial Port 1 (the backplane port) to output Bus
Monitor/Maintenance and Serial Port 2 to no output.
- dial
#92
to set Serial Port 1 to output SMDR and Serial Port 2
to output Bus Monitor/Maintenance data.
- dial
#93
to set Serial Port 1 to output SMDR data and Serial
Port 2 to no output.
Summary of Contents for VB-44210G
Page 22: ...2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 700 ...
Page 218: ......
Page 220: ...5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 700 ...
Page 258: ...6 2 DBS Manual Revised April 2000 DBS 2 3 9 2 700 ...
Page 394: ...Index 8 DBS Manual Revised April 2000 DBS 2 3 9 2 700 Index Section 700 Operation ...