8-9
8
Point the transmitter of the remote control at the receiver. When the signal is received correctly it will beep once.
(It beeps twice only when the unit starts operating.)
The signal can be received at a distance of about 6 meters. This distance should be used only as a guide.
It depends on battery strength.
Make sure nothing is between the remote control and the receiver that could block the signal.
Do not leave the remote in direct sunlight, where the wind from the air conditioner can blow directly on it, or near any other
heat source.
Take care not to drop, throw or wash the remote control with water.
The signal from the remote control may not be received in rooms with rapid start fluorescent lighting, inverter lights, plasma
displays, LCD televisions (monitor), etc. For more information, please contact the dealer where the product was purchased.
1
2
Fasten the remote control
mount with screws.
Fitting the remote
control in the mount.
Remote control mount
Press
Put in
Checking Addresses
When you press
on the remote control, its current address is shown in the display. If this address corresponds to the
address of a receiver
*
2
, the buzzer sounds. (If it is on ALL, the buzzer will always sound.)
If it is on ALL, it can be operated regardless of receiver addresses. Point the remote control at the receiver you wish to operate
and transmit.
*2
CZ-RWSL2 is a receiver. (Indoor unit)
8-8. Using the Remote Control
Wall Mount Use
• Press
from the location you wish to mount the remote
and make sure the signal is received correctly.
• Pull the remote control forward to remove it.
Don’t get the remote control too far away from the receiver.
This may cause a malfunction. Be sure to keep the remote control in the same room as the receiver.
remote control, addresses can be set up to avoid crosstalk. By setting the address switches on the receivers and matching
them with the number of addresses on the remote control, up to six indoor units can be controlled separately with the remote
control. (When using units in a flexible combination or operating multiple units simultaneously, as they are operated at the
same time, they cannot be controlled individually.) There are separate address settings, receiver addresses for the receivers*
and transmitter addresses for the remote control.
For more information, please contact the dealer where the product was purchased.
1
• The setting procedure is different for CZ-RWSY2 and Indoor Unit (CZ-RWSK2). (See Setting Addresses in the next page.)
• These settings are saved in nonvolatile memory in the remote control, so even when its batteries are changed, the settings
do not have to be made again.
* 1 CZ-RWST2 / CZ-RWST3 is of receivers (Inside the indoor unit); CZ-RWSL2 is of an operation panel. (Inside the indoor unit)
8-9. For Best Results
Point the remote control at the receiver.
When the signal is received correctly it will beep one time.
Avoid locating the remote control where it is covered, such as behind a curtain.
Keep it out in the open.
In both multi and single unit installations,
when more than one indoor unit is installed in the same room with a compatible
8-10. Addresses
Sec8.indd 9
2012/02/28 16:14:01
SM830211-07̲PAC-i.indb 9
SM830211-07̲PAC-i.indb 9
2013/09/17 23:03:33
2013/09/17 23:03:33
Summary of Contents for U-100PEY1E5
Page 536: ... MEMO 1 526 ...
Page 540: ... MEMO 2 4 ...
Page 549: ...3 9 3 3 1 Indoor Units Ducted Type S 36PN1E5 S 45PN1E5 S 50PN1E5 Electric Wiring Diagram ...
Page 551: ...3 11 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 552: ...3 12 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 553: ...3 13 3 3 2 Outdoor Units Single phase U 60PE1E5 U 71PE1E5 䡵 ...
Page 554: ...3 14 3 3 2 Outdoor Units Single phase U 100PE1E5 U 125PE1E5 U 140PE1E5 䡵 ...
Page 555: ...3 15 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 556: ...3 16 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 558: ...3 18 3 3 2 Outdoor Units 3 phase U 71PE1E8 ...
Page 559: ...3 19 3 3 2 Outdoor Units 3 phase U 100PEY1E8 U 125PEY1E8 ...
Page 560: ...3 20 3 3 2 Outdoor Units 3 phase U 100PE1E8 U 125PE1E8 U 140PE1E8 U 140PEY1E8 ...
Page 594: ...4 34 4 HIC PCB A746895 U 60PE1E5 U 71PE1E5 CN VDC U P V W N CN VDC 4WAY Valve CN 20S ...
Page 595: ...4 35 4 HIC PCB continued A746846 U 100PE1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 597: ...4 37 4 HIC PCB A746846 U 100PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 598: ...4 38 4 HIC PCB continued A746847 U 125PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 602: ...4 42 4 HIC PCB A747248 U 100PEY1E8 U 125PEY1E8 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 738: ... MEMO 8 34 ...
Page 739: ...201309 ...