1
1-407
Set screw only for transportation
Fig. 5-1
Fig. 5-2
Fig. 5-3
Fig. 5-4
Fig. 5-5
Rear panel
HOW TO INSTALL THE INDOOR UNIT
Wall Mounted Type (K1 Type)
Remove the Rear Panel from the Unit
(1) Remove and discard the set screw on the rear panel.
(Fig. 5-1)
(2) Press the 2
marks on the frame cover and disengage
the stationary tabs from the frame. (Fig. 5-2)
(3) Remove the rear panel by grasping the sections shown in
Fig. 5-3 and pulling it in the direction shown by the arrow.
N OT E
Tubing can be extended in 6 directions as shown in Fig. 5-5.
Select the direction you need providing the shortest run to the
outside unit.
When left tubing is to be done, switch the drain hose and
drain cap. (For details, refer to “Switching drain hose and
drain cap”.)
Make a Hole
(1) Place the rear panel from the indoor unit on the wall at the
location selected. Make sure the panel is horizontal, using
a carpenter’s level or tape measure to measure down from
the ceiling. Wait until after cutting the hole before attaching
the rear panel to the wall.
(2) Determine which side of the unit you should make the hole
for tubing and wiring. (Fig. 5-6)
N OT E
In the case of left-rear tubing, use the measurement points
158 mm from the marked position on the rear panel for precise
placement of the hose outlet. (Fig. 5-6)
(3) Before making the hole, check carefully that no studs or
pipes are directly run behind the spot to be cut.
CAUTION
Also avoid areas where
electrical wiring or conduits
are located.
The above precautions are also applicable if tubing goes
through the wall in any other location.
Fig. 5-6
marks
Rear panel
Rear panel
Left tubing
Left-rear
tubing
Left-downward tubing
Right-downward tubing
Right tubing
Right-rear tubing
(recommended)
m
m
2
3
1
m
m
8
5
1
Unit: mm
SM830211-07̲PAC-i.indb 407
SM830211-07̲PAC-i.indb 407
2013/09/17 22:48:31
2013/09/17 22:48:31
Summary of Contents for U-100PEY1E5
Page 536: ... MEMO 1 526 ...
Page 540: ... MEMO 2 4 ...
Page 549: ...3 9 3 3 1 Indoor Units Ducted Type S 36PN1E5 S 45PN1E5 S 50PN1E5 Electric Wiring Diagram ...
Page 551: ...3 11 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 552: ...3 12 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 553: ...3 13 3 3 2 Outdoor Units Single phase U 60PE1E5 U 71PE1E5 䡵 ...
Page 554: ...3 14 3 3 2 Outdoor Units Single phase U 100PE1E5 U 125PE1E5 U 140PE1E5 䡵 ...
Page 555: ...3 15 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 556: ...3 16 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 558: ...3 18 3 3 2 Outdoor Units 3 phase U 71PE1E8 ...
Page 559: ...3 19 3 3 2 Outdoor Units 3 phase U 100PEY1E8 U 125PEY1E8 ...
Page 560: ...3 20 3 3 2 Outdoor Units 3 phase U 100PE1E8 U 125PE1E8 U 140PE1E8 U 140PEY1E8 ...
Page 594: ...4 34 4 HIC PCB A746895 U 60PE1E5 U 71PE1E5 CN VDC U P V W N CN VDC 4WAY Valve CN 20S ...
Page 595: ...4 35 4 HIC PCB continued A746846 U 100PE1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 597: ...4 37 4 HIC PCB A746846 U 100PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 598: ...4 38 4 HIC PCB continued A746847 U 125PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 602: ...4 42 4 HIC PCB A747248 U 100PEY1E8 U 125PEY1E8 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 738: ... MEMO 8 34 ...
Page 739: ...201309 ...