1-160
1
Single -Type
1-1. Unit Specifi cations
PE1
7. Ducted Type S-71PN1E5 / U-71PE1E8
INDOOR
MODEL
S-71PN1E5
OUTDOOR
MODEL
U-71PE1E8
Branch pipe
MODEL
-
PERFORMANCE TEST CONDITION
ISO5151 / EN14825
POWER SUPPLY
ø, Hz
1ø 50Hz
3ø 50Hz
V
220
230
240
380
400
415
Min
Max
C
O
O
L
I
N
G
CAPACITY
kW
7.1
7.1
7.1
2.5
8.0
BTU/h
24200
24200
24200
8500
27300
CURRENT
A
1.12
1.08
1.04
3.25
3.10
3.00
-
-
INPUT POWER
W
140
140
140
2.010k
2.010k
2.010k
-
-
TOTAL W
-
2.150k
2.150k
2.150k
660
2.750k
ANNUAL CONSUMPTION TOTAL W 4
-
-
1075k
-
-
-
EER/EER CLASS
TOTAL(W/W) 5/("A"~"G")
-
-
-
3.30
3.30 / A
3.30
3.79
2.91
Erp
6
Pdsign
kW
-
-
-
-
7.1
-
SEER
(W/W)
-
-
-
-
5.2
-
Annual consumption
kWh
-
-
-
-
477
-
Class
-
-
-
-
A
-
POWER FACTOR
%
-
-
-
94
94
93
-
-
NOISE INDOOR
(H/M/L)
dB-A
43/41/36
Power Level dB
60/58/53
NOISE OUTDOOR
(H/L)
dB-A
48/-
Power Level dB
65/-
H
E
A
T
I
N
G
CAPACITY
kW
8.00
8.00
8.00
2.0
9.0
BTU/h
27300
27300
27300
6800
30700
CURRENT
A
1.12
1.08
1.04
3.35
3.20
3.10
-
-
INPUT POWER
W
140
140
140
2.120k
2.120k
2.120k
-
-
TOTAL W
-
2.260k
2.260k
2.260k
600
3.000k
COP/COP CLASS
TOTAL(W/W) 5/("A"~"G")
-
-
-
3.54
3.54 / B
3.54
3.33
3.00
Erp
6
Pdsign
kW
-
-
-
-
6.5
-
Tbivalen
°C
-
-
-
-
-10
-
SCOP
(W/W)
-
-
-
-
3.7
-
Annual consumption
kWh
-
-
-
-
2458
-
Class
-
-
-
-
A
-
POWER FACTOR
%
-
-
-
96
96
95
-
-
NOISE INDOOR
(H/M/L)
dB-A
43/41/36
-
⁄
⁄
Power Level dB
60/58/53
-
NOISE OUTDOOR
(H/L)
dB-A
-
50/-
⁄
⁄
Power Level dB
-
67/-
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
-
MAX CURRENT(A)/MAX INPUT POWER(W)
1.28/0.160k
1.24/0.160k
1.20/0.160k
7.0/4.150k
7.0/4.360k
7.0/4.530k
⁄
STARTING CURRENT(A)/COMP OUTPUT(W)
-
-
-
3.35/2.0k
3.20/2.0k
3.10/2.0k
⁄
NETWORK IMPEDANCE (
Ω
MAX.)
-
-
FM OUTPUT (W)
120
90
⁄
MOISTURE REMOVAL VOLUME
L/h(Pt/h)
4.2
(8.8)
-
External static pressure
Pa
50 (MIN10 - MAX80)
I/D AIR
FLOW
COOL
m
3
/min (ft
3
/min)
22
(777)
HEAT
m
3
/min (ft
3
/min)
22
(777)
O/D AIR
FLOW
COOL
m
3
/min (ft
3
/min)
60
(2119)
HEAT
m
3
/min (ft
3
/min)
60
(2119)
REFRIGERANT TYPE, AMOUNT
g
(oz)
R410A 2.35k
(82.9)
/
P
R
O
D
I
M
HEIGHT : H mm(inch)
250 (9-27/32)
996 (39-7/32)
/
WIDTH : W mm(inch)
1000 (+100) (39-5/16) (+3-15/16)
940 (37-1/32)
/
DEPTH : D mm(inch)
650 (25-19/32)
340 (13-13/32)
/
P
A
C
D
I
M
HEIGHT : H mm
338
1136
/
WIDTH : W mm
1211
1055
/
DEPTH : D mm
761
485
/
MASS
(NET) k
g
(lb)
32
71 (157)
/
(GROSS) k
g
(lb)
38
79 (175)
/
LAYERS LIMIT (actually)
6 (7)
2 (3)
Operation
Condition
Cool O.D(DBT)
18°C ~ 32°C
-15°C ~ 46°C
Heat O.D(DBT)
16°C ~ 30°C
-20°C ~ 24°C
P
I
P
I
N
G
PIPE DIAMETER mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
CONNECT METHOD, STD LENGTH m (ft)
fl
ared type, 5.0(16.4)
fl
ared type, 5.0(16.4)
PIPE LENGTH RANGE m (ft)
5 ~ 50
(16.4 ~ 164.0)
~
~
I/D&O/D HEIGHT DIFFERENCE m (ft)
15 (OD located lower) / 30 (OD located higher)
(49.2/98.4)
ADD GAS AMOUNT
g
/m (oz/ft)
50
(537.6)
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
30
(98.4)
*1
:
In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
:
If the EUROVENT Certifi ed models can be operated under the “extra-low” temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3
:
Network Impedance shall be applicable for EUROPE and CHINA models.
*4
:
The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5
:
EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6
:
SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
SM830211-07̲PAC-i.indb 160
SM830211-07̲PAC-i.indb 160
2013/09/17 22:46:37
2013/09/17 22:46:37
Summary of Contents for U-100PEY1E5
Page 536: ... MEMO 1 526 ...
Page 540: ... MEMO 2 4 ...
Page 549: ...3 9 3 3 1 Indoor Units Ducted Type S 36PN1E5 S 45PN1E5 S 50PN1E5 Electric Wiring Diagram ...
Page 551: ...3 11 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 552: ...3 12 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 553: ...3 13 3 3 2 Outdoor Units Single phase U 60PE1E5 U 71PE1E5 䡵 ...
Page 554: ...3 14 3 3 2 Outdoor Units Single phase U 100PE1E5 U 125PE1E5 U 140PE1E5 䡵 ...
Page 555: ...3 15 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 556: ...3 16 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 558: ...3 18 3 3 2 Outdoor Units 3 phase U 71PE1E8 ...
Page 559: ...3 19 3 3 2 Outdoor Units 3 phase U 100PEY1E8 U 125PEY1E8 ...
Page 560: ...3 20 3 3 2 Outdoor Units 3 phase U 100PE1E8 U 125PE1E8 U 140PE1E8 U 140PEY1E8 ...
Page 594: ...4 34 4 HIC PCB A746895 U 60PE1E5 U 71PE1E5 CN VDC U P V W N CN VDC 4WAY Valve CN 20S ...
Page 595: ...4 35 4 HIC PCB continued A746846 U 100PE1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 597: ...4 37 4 HIC PCB A746846 U 100PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 598: ...4 38 4 HIC PCB continued A746847 U 125PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 602: ...4 42 4 HIC PCB A747248 U 100PEY1E8 U 125PEY1E8 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 738: ... MEMO 8 34 ...
Page 739: ...201309 ...