5-63
5
P29 Lack of INV compressor wiring, INV compressor actuation failure
(including locked), DCCT failure
Error Diagnosis
2.
Error Detection Method
1.
Abnormal current is detected at DCCT before start-up.
Open-wire of compressor and/or backspin detected.
•
Start-up failed during overcurrent and/or step-out detected.
•
•
Secondary current is not detected during INV compressor is running.
•
1-1
1-2
2-1
Yes
No
1 Wiring
Correct wiring
connections
1-2
Disconnected parts, miswiring and/or poor connections (loose)
are observed in the connections of outdoor board(s) that are
connected by wiring from the HIC PC board. *1
Yes
No
Correct wiring
connections
Disconnected parts, miswiring and/or poor connections (loose)
are observed in the connections of HIC PC board(s) that are
connected by wiring to a compressor. *1
2-1
2-2
3-1
Yes
No
2
Compressor
wiring
Correct
2-2
Conditions such as burned terminal covers and/or discolored
terminals are observed at the connectors of the compressor
terminals. *1
Yes
No
Eliminate looseness
by changing the
terminals, or crimping
the terminals again.
Disconnections and/or miswiring is observed in the connections
of the compressor terminals. *1
4
4-1
Check the
outdoor control
PC board
Replace the control PC board and operate the unit.
3-1
3-2
4-1
Yes
No
3 Check the
HIC PC
boards
Replace the HIC board
3-2
Replace the HIC PC board and operate the unit. (Apply putty
and screws must not be loose) Does it operate normally?
Yes
No
See what happens.
See what happens.
The results of the pass/fail tests for the following HIC PC board
IPM show it to be outside the range of the resistance of a
conforming part.
Checking for looseness of compressor terminals by wiggling them has the adverse effect of loosening them, so do not do it.
Evaluate them by discoloration of wire insulation near the terminal.
*1
Measure with an analog tester. (Set to the k ohm range)
•
Measure the board by itself. (Remove wires connected from other parts.)
•
Measure using IPM terminals.
Conforming part resistance value (measure with an analog tester)
•
Excepting the parts of “
value is “0 = short-circuit”.
”, it is acceptable if a small resistance value appears as a reference value unless the
•
HIC board IPM Pass/Fail Tests
Tester terminals
-
Resistance value (ohm)
U
V
W
U
1 k to 5 k
V
1 k to 5 k
W
1 k to 5 k
NU
U
V
W
P
U
N
P
+
Tester terminals
+
Resistance value (ohm)
U
N
P
-
U
100 k to
100 k to
V
100 k to
W
100 k to
1 k to 5 k
1 k to 5 k
1 k to 5 k
5 k to 10 k 100 k to 100 k to 100 k to 100 k to
Excepting the parts of “
value is “0 = short-circuit”.
”, it is acceptable if a small resistance value appears as a reference value unless the
•
Tester terminals
-
Resistance value (ohm)
U
V
W
U
1 k to 10 k
V
1 k to 10 k
W
1 k to 10 k
HIC-
U
V
W
HIC+
-
C
I
H
+
C
I
H
+
Tester terminals
+
Resistance value (ohm)
-
C
I
H
+
C
I
H
-
U
20 k to
20 k to
V
20 k to
W
20 k to
1 k to 10 k 1 k to 10 k 1 k to 10 k 5 k to 20 k 20 k to
20 k to
20 k to
20 k to
SM830211-07̲PAC-i.indb 63
SM830211-07̲PAC-i.indb 63
2013/09/07 10:42:42
2013/09/07 10:42:42
Summary of Contents for U-100PEY1E5
Page 536: ... MEMO 1 526 ...
Page 540: ... MEMO 2 4 ...
Page 549: ...3 9 3 3 1 Indoor Units Ducted Type S 36PN1E5 S 45PN1E5 S 50PN1E5 Electric Wiring Diagram ...
Page 551: ...3 11 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 552: ...3 12 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 553: ...3 13 3 3 2 Outdoor Units Single phase U 60PE1E5 U 71PE1E5 䡵 ...
Page 554: ...3 14 3 3 2 Outdoor Units Single phase U 100PE1E5 U 125PE1E5 U 140PE1E5 䡵 ...
Page 555: ...3 15 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 556: ...3 16 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 558: ...3 18 3 3 2 Outdoor Units 3 phase U 71PE1E8 ...
Page 559: ...3 19 3 3 2 Outdoor Units 3 phase U 100PEY1E8 U 125PEY1E8 ...
Page 560: ...3 20 3 3 2 Outdoor Units 3 phase U 100PE1E8 U 125PE1E8 U 140PE1E8 U 140PEY1E8 ...
Page 594: ...4 34 4 HIC PCB A746895 U 60PE1E5 U 71PE1E5 CN VDC U P V W N CN VDC 4WAY Valve CN 20S ...
Page 595: ...4 35 4 HIC PCB continued A746846 U 100PE1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 597: ...4 37 4 HIC PCB A746846 U 100PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 598: ...4 38 4 HIC PCB continued A746847 U 125PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 602: ...4 42 4 HIC PCB A747248 U 100PEY1E8 U 125PEY1E8 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 738: ... MEMO 8 34 ...
Page 739: ...201309 ...