1-2. Dimensional Data
(A) Indoor Units: S-100PT2E5, S-125PT2E5, S-140PT2E5
Suspension
bolt
Ceiling
surface
Bracket
Hole position of indoor unit rear-side
(Figure shows view from front)
Unit
Within
50mm
Air intake
Air
discharge
Minimum 50cm
5
14
10
11 12
6
131
196
235
185
105
196
176
96
123
86
70
97
90
90
120
ø100 (cutout)
ø113
4-ø3.1
(Suspension bolt pitch)
1541
(Suspension
bolt pitch)
Approx. 2°
90 (Right drain position)
70 (Liquid tubing)
86 (Gas tubing)
(Closed with rubber stopper
at time of shipment.)
(Left drain position)
90
13
Service space
Over
250
Service space
Over
250
Tubing hole position on wall surface
(Figure shows view from front)
<Filter size>
(736 x 250 x 16) x 2 pcs.
Distance of each exposed
bolt must be of equal length
within 50mm.
unit :mm
Detailed view of intaking
outside air duct connection port
1 Drain port VP20 (inside diameter ø26mm, drain hose supplied)
2 Left drain position
3 Refrigerant liquid tubing (ø9.52mm, flare connection)
4 Refrigerant gas tubing (ø15.88mm, flare connection)
5 Cover of rear tubing hole
6 Tubing hole on wall surface (ø100mm)
7 Upper side tubing port
8 Right side drain hose outlet port (cutout)
9 Left side drain hose outlet port (cutout)
10 Left-rear side drain hose outlet port (cutout)
11 Power inlet port
12 Remote control wiring and inter-unit wiring inlet port
13 Wireless remote controller receiver installation location
14 Outside air intake duct connection port (ø100mm, cutout)
1590
1584
7
190
265
73
11
4
123
61
1 8
235
193
131
80
216
186
690
9
15
4
4
3
2
216
SM830211-07̲PAC-i.indb 247
SM830211-07̲PAC-i.indb 247
2013/09/17 22:47:45
2013/09/17 22:47:45
Summary of Contents for U-100PEY1E5
Page 536: ... MEMO 1 526 ...
Page 540: ... MEMO 2 4 ...
Page 549: ...3 9 3 3 1 Indoor Units Ducted Type S 36PN1E5 S 45PN1E5 S 50PN1E5 Electric Wiring Diagram ...
Page 551: ...3 11 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 552: ...3 12 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 553: ...3 13 3 3 2 Outdoor Units Single phase U 60PE1E5 U 71PE1E5 䡵 ...
Page 554: ...3 14 3 3 2 Outdoor Units Single phase U 100PE1E5 U 125PE1E5 U 140PE1E5 䡵 ...
Page 555: ...3 15 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 556: ...3 16 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 558: ...3 18 3 3 2 Outdoor Units 3 phase U 71PE1E8 ...
Page 559: ...3 19 3 3 2 Outdoor Units 3 phase U 100PEY1E8 U 125PEY1E8 ...
Page 560: ...3 20 3 3 2 Outdoor Units 3 phase U 100PE1E8 U 125PE1E8 U 140PE1E8 U 140PEY1E8 ...
Page 594: ...4 34 4 HIC PCB A746895 U 60PE1E5 U 71PE1E5 CN VDC U P V W N CN VDC 4WAY Valve CN 20S ...
Page 595: ...4 35 4 HIC PCB continued A746846 U 100PE1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 597: ...4 37 4 HIC PCB A746846 U 100PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 598: ...4 38 4 HIC PCB continued A746847 U 125PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 602: ...4 42 4 HIC PCB A747248 U 100PEY1E8 U 125PEY1E8 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 738: ... MEMO 8 34 ...
Page 739: ...201309 ...