1
1-316
Wiring System Diagrams
U2
R2
U1
R1
R2
R1
L
N
U2
U1
2
1
D
C
B
L
N
L
N
2
1
B
E
C
L
N
A
L
N
2
1
N
L
Power supply
220/230/240 V ~ 50Hz
Power supply
220/230/240 V ~ 50Hz
Ground
Ground
Indoor unit
(No. 2)
Indoor unit
(No. 1)
Ground
Ground
Ground
Ground
Outdoor unit (single-phase)
INV unit
Remote
controller
Power supply
220/230/240 ~ 50/60 Hz
WHT
BLK
N OT E
(1)
Wiring sample
Refer to Section “Recommended Wire Length and Wire
Diameter for Power Supply System” for the explanation
of “A”, “B”, “C”, “D” and “E” in the above diagrams.
(2) The basic connection diagram of the indoor unit shows the
terminal board, so the terminal boards in your equipment
may differ from the diagram.
(3) Refrigerant Circuit (R.C.) address should be set before
turning the power on.
(4) Regarding R.C. address setting, refer to the installation
instructions supplied with the remote controller unit
(Optional).
Auto address setting can be executed by remote controller
automatically.
Refer to the Installation Instructions supplied with the
remote controller (optional).
Outdoor Unit
L
1
2
N
Power
supply
Unit
control
line
5P terminal board
Earth
Use this screw when connecting
to ground for the unit control line.
Power supply line
Cord clamp
(Field supply)
Unit control line
Cord clamp A
Cord clamp B
Cord clamp C
SM830211-07̲PAC-i.indb 316
SM830211-07̲PAC-i.indb 316
2013/09/17 22:48:03
2013/09/17 22:48:03
Summary of Contents for U-100PEY1E5
Page 536: ... MEMO 1 526 ...
Page 540: ... MEMO 2 4 ...
Page 549: ...3 9 3 3 1 Indoor Units Ducted Type S 36PN1E5 S 45PN1E5 S 50PN1E5 Electric Wiring Diagram ...
Page 551: ...3 11 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 552: ...3 12 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 553: ...3 13 3 3 2 Outdoor Units Single phase U 60PE1E5 U 71PE1E5 䡵 ...
Page 554: ...3 14 3 3 2 Outdoor Units Single phase U 100PE1E5 U 125PE1E5 U 140PE1E5 䡵 ...
Page 555: ...3 15 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 556: ...3 16 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 558: ...3 18 3 3 2 Outdoor Units 3 phase U 71PE1E8 ...
Page 559: ...3 19 3 3 2 Outdoor Units 3 phase U 100PEY1E8 U 125PEY1E8 ...
Page 560: ...3 20 3 3 2 Outdoor Units 3 phase U 100PE1E8 U 125PE1E8 U 140PE1E8 U 140PEY1E8 ...
Page 594: ...4 34 4 HIC PCB A746895 U 60PE1E5 U 71PE1E5 CN VDC U P V W N CN VDC 4WAY Valve CN 20S ...
Page 595: ...4 35 4 HIC PCB continued A746846 U 100PE1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 597: ...4 37 4 HIC PCB A746846 U 100PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 598: ...4 38 4 HIC PCB continued A746847 U 125PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 602: ...4 42 4 HIC PCB A747248 U 100PEY1E8 U 125PEY1E8 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 738: ... MEMO 8 34 ...
Page 739: ...201309 ...