Single -Type
1-1. Unit Specifi cations
PEY1
4. Ceiling Type S-71PT2E5 / U-71PEY1E5
INDOOR
MODEL
S-71PT2E5
PANEL
MODEL
OUTDOOR
MODEL
U-71PEY1E5
Branch pipe
MODEL
-
PERFORMANCE TEST CONDITION
ISO5151 / EN14825
POWER SUPPLY
ø, Hz
1ø 50Hz
1ø 50Hz
V
220
230
240
220
230
240
Min
Max
C
O
O
L
I
N
G
CAPACITY
kW
7.1
7.1
7.1
2.0
7.7
BTU/h
24200
24200
24200
6800
26300
CURRENT
A
0.45
0.44
0.43
10.8
10.3
9.85
-
-
INPUT POWER
W
55
55
55
2.155k
2.155k
2.155k
-
-
TOTAL W
-
2.210k
2.210k
2.210k
325
2.820k
ANNUAL CONSUMPTION TOTAL kWh 4
-
-
1105
-
-
-
EER/EER CLASS
TOTAL(W/W) 5/("A"~"G")
-
-
-
3.21
3.21 / A
3.21
6.15
2.73
Erp
6
Pdsign
kW
-
-
-
-
7.1
-
SEER
(W/W)
-
-
-
-
6.1
-
Annual consumption
kWh
-
-
-
-
408
-
Class
-
-
-
-
A++
-
POWER FACTOR
%
-
-
-
91
91
91
-
-
NOISE INDOOR
(H/M/L)
dB-A
39/35/31
-
Power Level dB
57/53/49
-
NOISE OUTDOOR
(H/L)
dB-A
50/-
Power Level dB
70/-
H
E
A
T
I
N
G
CAPACITY
kW
7.1
7.1
7.1
1.8
8.1
BTU/h
24200
24200
24200
6100
27600
CURRENT
A
0.45
0.44
0.43
8.75
8.35
8.00
-
-
INPUT POWER
W
55
55
55
1.765k
1.765k
1.765k
-
-
TOTAL W
-
1.820k
1.820k
1.820k
275
2.510k
COP/COP CLASS
TOTAL(W/W) 5/("A"~"G")
-
-
-
3.90
3.90 / A
3.90
6.55
3.23
Erp
6
Pdsign
kW
-
-
-
-
6.0
-
Tbivalen
°C
-
-
-
-
-6
-
SCOP
(W/W)
-
-
-
-
4.0
-
Annual consumption
kWh
-
-
-
-
2100
-
Class
-
-
-
-
A+
-
POWER FACTOR
%
-
-
-
92
92
92
-
-
NOISE INDOOR
(H/M/L)
dB-A
39/35/31
-
⁄
⁄
Power Level dB
57/53/49
-
NOISE OUTDOOR
(H/L)
dB-A
-
52/-
⁄
⁄
Power Level dB
-
70/-
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
-
MAX CURRENT(A)/MAX INPUT POWER(W)
0.45/55
0.44/55
0.43/55
18.0/3.60k
18.0/3.77k
18.0/3.93k
⁄
STARTING CURRENT(A)/COMP OUTPUT(W)
-
-
-
10.8/1.0k
10.3/1.0k
9.85/1.0k
⁄
NETWORK IMPEDANCE (
Ω
MAX.)
-
-
FM OUTPUT (W)
74
90
⁄
MOISTURE REMOVAL VOLUME
L/h(Pt/h)
4.2
(8.8)
-
External static pressure
Pa
-
I/D AIR
FLOW
COOL
m
3
/min (ft
3
/min)
21
(742)
HEAT
m
3
/min (ft
3
/min)
21
(742)
O/D AIR
FLOW
COOL
m
3
/min (ft
3
/min)
39
(1377)
HEAT
m
3
/min (ft
3
/min)
39
(1377)
REFRIGERANT TYPE, AMOUNT
g
(oz)
R410A 1.70k
(60.0)
/
P
R
O
D
I
M
HEIGHT : H mm(inch)
235
9-1/4
569 22-13/32
/
WIDTH : W mm(inch)
1275
50-3/16
790 31-7/64
/
DEPTH : D mm(inch)
690
27-5/32
285 11-7/32
/
P
A
C
D
I
M
HEIGHT : H mm
360
645
/
WIDTH : W mm
1340
921
/
DEPTH : D mm
820
386
/
MASS
(NET) k
g
(lb)
33
(73)
42
(93)
/
(GROSS) k
g
(lb)
42
(93)
46
(101)
/
LAYERS LIMIT (actually)
9 (10)
4 (5)
Operation
Condition
Cool O.D(DBT)
18°C ~ 32°C
-10°C ~ 43°C
Heat O.D(DBT)
16°C ~ 30°C
-15°C ~ 24°C
P
I
P
I
N
G
PIPE DIAMETER mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
CONNECT METHOD, STD LENGTH m (ft)
fl
ared type, 5.0(16.4)
fl
ared type, 5.0(16.4)
PIPE LENGTH RANGE m (ft)
5 ~ 50
(16.4 ~ 164.0)
~
~
I/D&O/D HEIGHT DIFFERENCE m (ft)
15 (OD located lower) / 30 (OD located higher)
(49.2/98.4)
ADD GAS AMOUNT
g
/m (oz/ft)
40
(0.430)
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
20
(65.6)
*1
:
In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
:
If the EUROVENT Certifi ed models can be operated under the “extra-low” temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3
:
Network Impedance shall be applicable for EUROPE and CHINA models.
*4
:
The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5
:
EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
SM830211-07̲PAC-i.indb 198
SM830211-07̲PAC-i.indb 198
2013/09/17 22:47:05
2013/09/17 22:47:05
Summary of Contents for U-100PEY1E5
Page 536: ... MEMO 1 526 ...
Page 540: ... MEMO 2 4 ...
Page 549: ...3 9 3 3 1 Indoor Units Ducted Type S 36PN1E5 S 45PN1E5 S 50PN1E5 Electric Wiring Diagram ...
Page 551: ...3 11 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 552: ...3 12 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 553: ...3 13 3 3 2 Outdoor Units Single phase U 60PE1E5 U 71PE1E5 䡵 ...
Page 554: ...3 14 3 3 2 Outdoor Units Single phase U 100PE1E5 U 125PE1E5 U 140PE1E5 䡵 ...
Page 555: ...3 15 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 556: ...3 16 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 558: ...3 18 3 3 2 Outdoor Units 3 phase U 71PE1E8 ...
Page 559: ...3 19 3 3 2 Outdoor Units 3 phase U 100PEY1E8 U 125PEY1E8 ...
Page 560: ...3 20 3 3 2 Outdoor Units 3 phase U 100PE1E8 U 125PE1E8 U 140PE1E8 U 140PEY1E8 ...
Page 594: ...4 34 4 HIC PCB A746895 U 60PE1E5 U 71PE1E5 CN VDC U P V W N CN VDC 4WAY Valve CN 20S ...
Page 595: ...4 35 4 HIC PCB continued A746846 U 100PE1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 597: ...4 37 4 HIC PCB A746846 U 100PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 598: ...4 38 4 HIC PCB continued A746847 U 125PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 602: ...4 42 4 HIC PCB A747248 U 100PEY1E8 U 125PEY1E8 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 738: ... MEMO 8 34 ...
Page 739: ...201309 ...