8-21
8
8-17. CZ-RWSL2
1. Accessories
Installing the Display/Operation Panel
Resin Panel
Installing the Operation Panel
(1)
(2)
(3)
Remove the 2 screws and remove cover A from the back of the panel. (Fig. 8-15)
Fasten the operation panel to the location in the diagram below with the 2 enclosed screws (4
X
10). (Fig. 8-16)
Pass the wiring for the display (W2, 6P white connector) through the back of the panel.
Installing the Display
(1) Cover B is fitted inside cover A, so remove the 1 screw and detach it by pressing on it from the front side of the panel.
(Fig. 8-17)
(2) Connect the wiring (W2) for the display that is sticking out from the operation panel and fit the display into the panel.
Make sure the 6P white connector is firmly connected all the way in.
(3) Bend the lead wire of the display into shape so it does not come in contact with the louver shaft. There is a groove in the
circled part in diagram 3 that is for passing wire through; press the lead wire into this groove so there is no slack in it.
(4) Attach cover A. When doing so, press it securely into the place indicated by the arrow in Fig 8-18.
(5) Shape the lead wire of the operation panel appropriately and fasten it with the enclosed plastic clamp.
(6) Install the ceiling panel.
Fig. 8-15
Fig. 8-16
Fig. 8-18
Fig. 8-17
1
Operation Panel
1
2
Display
1
3
1
Remote Control
4
1
r
e
d
l
o
H
l
o
r
t
n
o
C
e
t
o
m
e
R
2
Dry-cell Batteries
4
1
Users Manual
5
6
Truss Self-Tapping Screws
4 X 16
2
7
Pan Head Self-Tapping Screws
4 X 10
4
8
Plastic Clamp L150
3
Cover A
Enclosed screws
(4 X 10)
Operation Panel
Display wiring (W2)
Cover B
Connect
Display
No.
Accessories
Quantity
No.
Accessories
Quantity
Sec8.indd 21
2012/02/28 16:14:02
SM830211-07̲PAC-i.indb 21
SM830211-07̲PAC-i.indb 21
2013/09/17 23:03:36
2013/09/17 23:03:36
Summary of Contents for U-100PEY1E5
Page 536: ... MEMO 1 526 ...
Page 540: ... MEMO 2 4 ...
Page 549: ...3 9 3 3 1 Indoor Units Ducted Type S 36PN1E5 S 45PN1E5 S 50PN1E5 Electric Wiring Diagram ...
Page 551: ...3 11 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 552: ...3 12 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 553: ...3 13 3 3 2 Outdoor Units Single phase U 60PE1E5 U 71PE1E5 䡵 ...
Page 554: ...3 14 3 3 2 Outdoor Units Single phase U 100PE1E5 U 125PE1E5 U 140PE1E5 䡵 ...
Page 555: ...3 15 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 556: ...3 16 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 558: ...3 18 3 3 2 Outdoor Units 3 phase U 71PE1E8 ...
Page 559: ...3 19 3 3 2 Outdoor Units 3 phase U 100PEY1E8 U 125PEY1E8 ...
Page 560: ...3 20 3 3 2 Outdoor Units 3 phase U 100PE1E8 U 125PE1E8 U 140PE1E8 U 140PEY1E8 ...
Page 594: ...4 34 4 HIC PCB A746895 U 60PE1E5 U 71PE1E5 CN VDC U P V W N CN VDC 4WAY Valve CN 20S ...
Page 595: ...4 35 4 HIC PCB continued A746846 U 100PE1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 597: ...4 37 4 HIC PCB A746846 U 100PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 598: ...4 38 4 HIC PCB continued A746847 U 125PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 602: ...4 42 4 HIC PCB A747248 U 100PEY1E8 U 125PEY1E8 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 738: ... MEMO 8 34 ...
Page 739: ...201309 ...