1
1-300
1-11. Installation instructions
U-50PE1E5, U-60PEY1E5, U-71PEYE5
ACCESSORIES SUPPLIED WITH OUTDOOR UNIT
Part Name
Figure
Q’ty
Remarks
Operating
Instructions
A5-size
1
Part Name
Figure
Q’ty
Remarks
Installation
Instructions
1
Included this
instructions
SELECTING THE INSTALLATION SITE
AVOID:
heat sources and exhaust fans, etc.
damp, humid or uneven locations.
DO:
choose a place as cool as possible.
choose a place that is well ventilated and outside air
temperature does not exceed maximum 45°C constantly.
allow enough room around the unit for air intake/exhaust
and possible maintenance.
use lug bolts or equal to bolt down unit, reducing vibration
and noise.
If cooling operation is to be used when the outdoor air
temperature is –5°C or below, install a duct on the outdoor
unit.
Exhaust fan
Heat source
Outdoor
unit
Hot air
Installation space for outdoor unit (single-phase)
Install the outdoor unit with a sufficient space around the outdoor unit for operation and maintenance.
(1)
Obstructions on the left side, right side and rear side (Front side and above the unit are opened).
A
B
C
A
B
C
5 cm
or more
25 cm
or more
5 cm
or more
(2)
Obstructions on the front side and rear side (Left side, right side and above the unit are opened).
A
B
*A
B
50 cm
or more
5 cm
or more
* For compressor replacement, 50 cm or more is required on
the front side even when using the air discharge chamber.
If the height of the obstruction is above 2 m, over 1 m of
space is required.
SM830211-07̲PAC-i.indb 300
SM830211-07̲PAC-i.indb 300
2013/09/17 22:48:00
2013/09/17 22:48:00
Summary of Contents for U-100PEY1E5
Page 536: ... MEMO 1 526 ...
Page 540: ... MEMO 2 4 ...
Page 549: ...3 9 3 3 1 Indoor Units Ducted Type S 36PN1E5 S 45PN1E5 S 50PN1E5 Electric Wiring Diagram ...
Page 551: ...3 11 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 552: ...3 12 3 3 2 Outdoor Units Single phase U 50PE1E5 ...
Page 553: ...3 13 3 3 2 Outdoor Units Single phase U 60PE1E5 U 71PE1E5 䡵 ...
Page 554: ...3 14 3 3 2 Outdoor Units Single phase U 100PE1E5 U 125PE1E5 U 140PE1E5 䡵 ...
Page 555: ...3 15 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 556: ...3 16 3 3 2 Outdoor Units Single phase U 60PEY1E5 U 71PEY1E5 ...
Page 558: ...3 18 3 3 2 Outdoor Units 3 phase U 71PE1E8 ...
Page 559: ...3 19 3 3 2 Outdoor Units 3 phase U 100PEY1E8 U 125PEY1E8 ...
Page 560: ...3 20 3 3 2 Outdoor Units 3 phase U 100PE1E8 U 125PE1E8 U 140PE1E8 U 140PEY1E8 ...
Page 594: ...4 34 4 HIC PCB A746895 U 60PE1E5 U 71PE1E5 CN VDC U P V W N CN VDC 4WAY Valve CN 20S ...
Page 595: ...4 35 4 HIC PCB continued A746846 U 100PE1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 597: ...4 37 4 HIC PCB A746846 U 100PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 598: ...4 38 4 HIC PCB continued A746847 U 125PEY1E5 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 602: ...4 42 4 HIC PCB A747248 U 100PEY1E8 U 125PEY1E8 CN VDC U V W CN VDC 4WAY Valve CN 20S P NU ...
Page 738: ... MEMO 8 34 ...
Page 739: ...201309 ...