Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-180
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
Loss of Signal Counter
Software Version: CPC-B Version 4.0 or higher
Address:
Master Cabinet: FF1 8# 4# 4# 3# 4# (0-9000)#
Slave Cabinet:
FF1 8# 4# 5# 3# 4# (0-9000)#
Description
Determines how many instances of loss of signal must occur before a Signal
Loss Alarm FF key is lit. Signal loss occurs when the incoming T1 signal is
not received for more than 150 ms. The FF key lights when the counter
exceeds the specified number within a 24-hour period.
For instructions on programming T1 alarm keys, see the
T1 Reference
Manual (Section 500).
Programming
Related Programming
Red Alarm Relay: FF1 8# 4# (4 or 5)# 4# 2# (0 or 1)#
Red Alarm Detection: FF1 8# 4# (4 or 5)# 2# 1# (0 or 1)#
FF1 8# 4# (4 or 5)# 3# 4# (0-9000)#
4=Master Cabinet
5=Slave Cabinet
Instances of Signal Loss that must occur
within a 24-hour period before a
Signal Loss Alarm FF key is lit
Default:
9000