Section 400-Programming
Chapter 1. System Programming (FF1)
DBS-2.3/9.2-400
DBS Manual - Revised April 2000
Page 1-195
Incoming Dialing Method
Software Version: CPC-B Version 4.0 or higher
Address:
FF1 8# 4# 6# (Trunk)# 7# (0 or 1)#
Description
Determines whether the system expects dial-pulse or DTMF digits for
incoming DID or DNIS calls over the T1.
Programming
Notes
Power-Cycling Requirement.
For changes to this parameter to take effect,
the system must be turned off, then back on.
Hardware Requirement.
An MFR card is required for DID/DNIS if DTMF
signaling is used.
FF1 8# 4# 6# (1-64)# 7# (0 or 1)#
Trunk Number (1-64)
0=Dial-Pulse (10 PPS)
1=DTMF