Section 400-Programming
Chapter 1. System Programming (FF1)
DBS-2.3/9.2-400
DBS Manual - Revised April 2000
Page 1-119
Extension Transfer Recall Timer for Intercom Calls
Software Version: CPC-AII (all versions) and CPC-B Version 2.0 or higher
Address: FF1 3# 25# (0-12)#
Description
This timer determines how long a transferred intercom call will ring at
another extension before it recalls back to the transferring extension (140
seconds by default).
Programming
Table 1-32 Extension Transfer Recall Timer values for intercom calls
Related Programming
Extension Transfer Recall Timer for CO Calls: FF1 3# 5# (0-12)#
Notes
Call Forward Interaction.
If a call is transferred to an extension that has
Call Forwarding turned on, the call will follow the call forwarding path if the
Call Forward-No Answer Timer is less than the Recall Timer.
Setting
Value
0
No recall
1
20 seconds
2
40 seconds
3
60 seconds
4
80 seconds
5
100 seconds
6
120 seconds
7
140 seconds
8
160 seconds
9
180 seconds
10 200
seconds
11
220 seconds
12
240 seconds
FF1 3# 25# (0-12)#
Extension Transfer Recall Timer setting for intercom calls
Default:
7 (140 seconds)
(see table below)
Summary of Contents for DBS-2.3-400
Page 24: ...Intro 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 46: ...Page 1 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 250: ...Page 2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 364: ...Page 5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 428: ...Page 9 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 434: ...Page 10 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...