Digital Pad Settings
Software Version: CPC-B Version 4.0 or higher
Address:
FF1 8# 4# 3# (1-12)# (1-12)# (0-30)#
Description
Adjusts the volume of connections made via the T1. Default volume levels
are included for connections between different types of terminals or circuits.
For example, a KTel-to-T1 connection may use one volume setting, while an
SLT-to-T1 connection may use another.
The volume settings are controlled by changing a pad number, which in turn
changes the loss or gain of the connection. In most cases, the default pad
settings do not need to be changed.
If the volume level of a connection is unsatisfactory, include the Receiving
and Sending circuit types in this program, and then adjust the volume by
assigning a new pad number.
Programming
Table 1-47. Digital Pad Settings - circuit types
Circuit Type
Setting
Value
Notes
1
K-Tel
2
SLT
3
Data
Reserved for future use.
4
Analog CO Trunk
5
T1 master
6
T1 slave
7
Option 1
Can be used to assign unique
pad levels to circuits that require
special volume levels.
8
Option 2
9
DTMF
Reserved for future use.
10
CONF (SCC)
Reserved for future use.
11
Tone 1 (MFR 1)
Reserved for future use.
12
Tone 2 (MFR 2)
Reserved for future use.
FF1 8# 4# 3# (1-12)# (1-12)# (0-30)#
Receiving Sending Pad No.
Circuit Type Circuit Type (see table,
(“To” Side) (“From” Side) next page)
(see table below)
Summary of Contents for DBS-2.3-400
Page 24: ...Intro 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 46: ...Page 1 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 250: ...Page 2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 364: ...Page 5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 428: ...Page 9 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 434: ...Page 10 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...