Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-178
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
Slip Counter
Software Version: CPC-B Version 4.0 or higher
Address:
Master Cabinet: FF1 8# 4# 4# 3# 2# (0-9000)#
Slave Cabinet:
FF1 8# 4# 5# 3# 2# (0-9000)#
Description
Determines how many slips occur before a Slip Alarm FF key is lit. (“Slips”
are losses of data bits due to framing errors.) The FF key lights when the
counter exceeds the specified number within a 24-hour period.
This parameter also determines the number of slips that can occur before the
system switches to the next clock source, at which time
the slip error
counter for the first clock source is reset, and all phone calls in progress
are disconnected.
It takes 20 seconds for the T1 to reboot.
For instructions on programming T1 alarm keys, see the
T1 Reference
Manual (Section 500).
Programming
Related Programming
Sync Source 1: FF1 8# 4# 1# 2# (1-3)#
Sync Source 2: FF1 8# 4# 1# 3# (0-3)#
Sync Source 3: FF1 8# 4# 1# 4# (0-3)#
Slip FF Key: FF5 (ExtPort)# (Key)# CONF (102# or 122#)#
FF1 8# 4# (4 or 5)# 3# 2# (0-9000)#
4=Master Cabinet
5=Slave Cabinet
Number of Slips that must occur
within a 24-hour period before a
Slip Alarm FF key is lit
Default:
9000
Summary of Contents for DBS-2.3-400
Page 24: ...Intro 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 46: ...Page 1 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 250: ...Page 2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 364: ...Page 5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 428: ...Page 9 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 434: ...Page 10 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...