Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-98
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
Extension Transfer Recall Timer for CO Calls
Software Version: All Versions
Address: FF1 3# 5# (0-12)#
Description
When an extension transfers a trunk call to another extension or to a hunt
group, the transferred call will recall to the extension if it is not answered.
This timer determines how long a transferred trunk call will go unanswered
before it recalls (140 seconds by default).
Programming
Table 1-12. Extension Transfer Recall Timer values for CO calls
Related Programming
Attendant Call Reversion Timer for CO Calls: FF1 3# 10# (0-12)#
Notes
Recall Treatment for CO Calls.
If a trunk recall is unanswered, it will revert
to the Attendant phone after ringing for the amount of time set in the
Attendant Call Reversion Timer.
Setting
Value
0
No recall
1
20 seconds
2
40 seconds
3
60 seconds
4
80 seconds
5
100 seconds
6
120 seconds
7
140 seconds
8
160 seconds
9
180 seconds
10
200 seconds
11
220 seconds
12
240 seconds
FF1 3# 5# (0-12)#
Extension Transfer Recall Timer setting for CO calls
Default:
7 (140 seconds)
(see table below)
Summary of Contents for DBS-2.3-400
Page 24: ...Intro 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 46: ...Page 1 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 250: ...Page 2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 364: ...Page 5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 428: ...Page 9 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 434: ...Page 10 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...