Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-188
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
Relay Reset
Software Version: CPC-B Version 4.0 or higher
Address:
Master Cabinet: FF1 8# 4# 4# 4# 6# (0 or 1)#
Slave Cabinet:
FF1 8# 4# 5# 4# 6# (0 or 1)#
Description
Determines whether the T1 alarm relay is cleared (opened) automatically or
manually.
• If cleared automatically, the relay is opened approximately one second
after the alarm condition ceases.
• If cleared manually, the relay can be opened by entering the Alarm Relay
Clear code:
- First, enter the programming authorization code --
#98 9999
- Then enter one of the following codes:
ON/OFF #94 8 (for Master Cabinet)
ON/OFF #95 8 (for Slave Cabinet)
Programming
Related Programming
Yellow Alarm Relay: FF1 8# 4# 4/5# 4# 1# (0-15)#
Red Alarm Relay: FF1 8# 4# 4/5# 4# 2# (0-15)#
Sync Loss Relay: FF1 8# 4# 4/5# 4# 3# (0-15)#
Frame Loss Relay: FF1 8# 4# 4/5# 4# 4# (0-15)#
AIS Relay: FF1 8# 4# 4/5# 4# 5# (0-15)#
FF1 8# 4# (4 or 5)# 4# 6# (0 or 1)#
4=Master Cabinet
5=Slave Cabinet
0=Automatically cleared
1=Must be manually cleared