Chapter 7. Toll Restriction (FF7)
Section 400-Programming
Page 7-22
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
Night TRS Types 0-7 for Trunks
Software Version: All Versions
Address: FF7 8# (ExtPort)# (Trunk)# (0-7)#
Description
Use this program to assign TRS types to the trunks on an individual
extension. These TRS types will apply when the system is in “Night” and
“Night 2” mode.
For a review of TRS types, see
“An Overview of Toll Restrictions”
on page
7-2.
Programming
Related Programming
Automatic Night Mode Start Time: FF1 3# 1# HHMM#
Automatic Night 2 Mode Start Time: FF1 3# 30# HHMM#
Toll Restriction: all FF7 addresses
FF7 8# (1-144)# (1-33 or 1-65)# (0-7)#
Extension Port Trunk TRS Type 0-7
Default:
7 (all calls
Note:
Enter “65” (for CPC-AII/B) or “33” (for CPC-A) to apply
allowed)
all trunks to the TRS type.