AEC Disconnect
Software Version: CPC-AII (all versions); CPC-B Version 5.0 or higher
Address: FF3 (ExtPort)# 46# (0 or 1)#
Description
The VB-43621A version of the AEC card can be set to provide a positive
disconnect signal. Use this address to enable or disable the AEC disconnect
signal on individual extension(s).
If this option is enabled, analog extension ports will send a disconnect signal
(open loop) upon hangup. Sending this signal allows quick disconnection
from third-party voice mail systems.
NOTE:
This feature requires CPC-A 3.3 or higher, CPC-AII (all versions),
or CPC-B 5.0 or higher. The address for CPC-A is FF3 (ExtPort)# 35#.
Programming
Related Programming
SLT Disconnect Signal Duration: FF1 2# 1# 35# (0-15)#
FF3 (1-144)# 46# (0 or 1)#
0=Disabled
1=Enabled