Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-62
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
SMDR Printing Mode 3: Header Title
Software Version: All Versions
Address: FF1 2# 2# 8# (0 or 1)#
Description
The SMDR data sent to Serial Port CN6 can be programmed to include a
header title (inserted every 60 lines on the SMDR report); or the header title
can be excluded from the report. By default, the header title is excluded.
The header title identifies the SMDR information in each column on the
report -- “Time,” “Duration,” “CO#”, etc.
Programming
Notes
Bus Monitor Mode Interaction.
If the DBS is switched to Bus Monitor
mode for troubleshooting, the SMDR mode must be reactivated to resume
SMDR output. The SMDR mode can be reactivated from any Attendant
phone by pressing ON/OFF - #93 - ON/OFF.
FF1 2# 2# 8# (0 or 1)#
0=Do not include the header title.
1=Include the header title.