SLT Hookflash
Software Version: CPC-B Version 3.1 or higher
Address: FF3 (ExtPort)# 38# (0 or 1)#
Description
This setting determines what happens when a single-line telephone (SLT)
user hookflashes when the SLT has one active call and one held call.
Programming
FF3 (1-144)# 38# (0 or 1)#
Extension Port
0=Brokers Hold (hookflash toggles
1=Hookflash creates a three-party
between the two parties).
conference.