Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-136
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
DID Hardware and Power Requirements.
The DID trunk card is required
(each DID card provides 8 ports). The DID trunk card requires an external,
-48V power supply. Also, SCC-B Card Version 1.2 or higher is required.
See
Section 300-Installation
for cabling instructions.
Dial Pulse Requirement.
The DID trunk card requires dial-pulse dialing.
Digit Length Requirement.
The DBS only supports 4-digit DID numbers.
DID Ring Control.
Ringing for the DID number at the assigned extension(s)
is controlled by the DID Flexible Ringing Assignments address (FF1 8# 5#).