Chapter 1. System Programming (FF1)
Section 400-Programming
Page 1-44
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
AEC Disconnect Signal Duration
Software Version: CPC-AII (all versions) and CPC-B Version 5.0 or higher
Address: FF1 2# 1# 35# (0-15)#
Description
Use this address to set the duration of a positive disconnect signal sent from
analog extension ports (VB-43621A version of the AEC card). Sending this
signal allows quick disconnect from third-party voice mail systems. By
default, no disconnect signal is sent.
This address applies to CPC-AII and CPC-B. The AEC Disconnect Signal
Duration address for CPC-A (Version 3.3 or higher) is FF1 2# 1# 23# (0-
15)#.
The sending of the AEC disconnect signal can be enabled or disabled on
individual extensions using FF3 (ExtPort)# 46#.
Programming
Table 1-4. AEC Disconnect Signal Duration values
Setting
Value
0
No disconnect signal sent
1
100 ms
2
200 ms
3
300 ms
4
400 ms
5
500 ms
6
600 ms
7
700 ms
8
800 ms
9
900 ms
10
1 second
11
1.5 seconds
12
2 seconds
13
2.5 seconds
FF1 2# 1# 35# (0-15)#
AEC Disconnect Signal Duration setting
Default:
0 (no signal sent)
(see table below)
Summary of Contents for DBS-2.3-400
Page 24: ...Intro 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 46: ...Page 1 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 250: ...Page 2 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 364: ...Page 5 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 428: ...Page 9 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...
Page 434: ...Page 10 2 DBS Manual Revised April 2000 DBS 2 3 9 2 400 ...