![Panasonic DBS-2.3-400 Programming Manual Download Page 322](http://html.mh-extra.com/html/panasonic/dbs-2-3-400/dbs-2-3-400_programming-manual_279501322.webp)
Chapter 3. Extension Programming (FF3)
Section 400-Programming
Page 3-48
DBS Manual - Revised April 2000
DBS-2.3/9.2-400
Digital SLT Receiving Volume
Software Version: CPC-AII (all versions); CPC-B Version 3.1 or higher
Address: FF3 (ExtPort)# 40# (0 or 1)#
Description
The receiver (hearing) volume of the handset on a digital single-line
telephone (DSLT) can be set to “normal” or “loud.”
The “loud” setting gives a +6 dB gain over the “normal” setting
(approximately twice as loud).
Programming
FF3 (1-144)# 40# (0 or 1)#
Extension Port
0=Normal
1=Loud