F-15
Appendices
V440-F C-Mount Code Reader User Manual
F-
10
C
a
p
ture
Mo
de
F
F-10-
1 Number
of Captur
es
F-10 Capture Mode
Definition:
Capture Mode
relates to the way in which images are captured and processed.
Serial Cmd:
<
K241,
capture mode
,number of captures,rapid capture mode,continuous capture
burst count,images per read cycle limit,read cycle history
>
Default:
Continuous Capture
Options:
0 = Rapid Capture
1 = Continuous Capture
Rapid Capture
Definition:
In a rapid capture mode, one or multiple captures can be taken at an interval specified
by the time-between-captures parameter. In this mode, the only limiting time factor is
integration and transfer timing.
Continuous Capture
Usage:
Continuous Capture
is useful in applications with slower line speeds or where symbol
spacing may be random or not time-dependent.
Definition:
In
Continuous Capture Mode
, image captures are taken throughout the read cycle in a
multi-buffered format (see diagram below). The reader begins processing the first
captured image at the same time that it captures the second image. Captures will continue
occurring throughout the read cycle until an end condition occurs, such as a timeout, a
new trigger, the last frame in a capture sequence, or a combination of the above.
F-10-1 Number of Captures
Usage:
Number of Captures
is used to specify the number of captures to be processed in
Rapid Capture Mode
.
Definition:
Sets the total number of captures that are processed during a read cycle in
Rapid
Capture Mode
. This feature is used in conjunction with
Capture Timing
parameters
to specify the capture sequence of a rapid capture read cycle. This may be more than
the total buffers available and may require tuning to optimize large capture counts,
especially when more than the buffer count is requested. It may not be possible to
capture all images when such a large capture count is requested.
Serial Cmd:
<
K241,
capture mode,
number of captures
,rapid capture mode,continuous capture
burst count,images per read cycle limit,read cycle history
>
Default:
1
Options:
1 to 255 (No limit)
Processing time
End of
read cycle
Capture
Start of Read
Cycle
1 2 3
4
5
Summary of Contents for V440-F
Page 1: ...Z452 E 01 84 9000440 02 Rev A V440 F C Mount Code Reader User Manual...
Page 31: ...1 Overview of WebLink Interface 1 16 V440 F C Mount Code Reader User Manual...
Page 139: ...4 Setup 4 76 V440 F C Mount Code Reader User Manual...
Page 183: ...7 Terminal 7 6 V440 F C Mount Code Reader User Manual...
Page 243: ...Appendices A 22 V440 F C Mount Code Reader User Manual...
Page 249: ...Appendices C 4 V440 F C Mount Code Reader User Manual...
Page 283: ...Appendices E 10 V440 F C Mount Code Reader User Manual...
Page 399: ...Appendices I 18 V440 F C Mount Code Reader User Manual...
Page 423: ...Appendices K 14 V440 F C Mount Code Reader User Manual...
Page 437: ...Appendices L 14 V440 F C Mount Code Reader User Manual...
Page 471: ...Appendices N 18 V440 F C Mount Code Reader User Manual...
Page 481: ...Appendices O 10 V440 F C Mount Code Reader User Manual...
Page 493: ...Appendices R 8 V440 F C Mount Code Reader User Manual...
Page 499: ...Appendices S 6 V440 F C Mount Code Reader User Manual...