Appendices
N-10
V440-F C-Mount Code Reader User Manual
N-8 Global Sorting Options
Note:
Regular
Output Filter
,
<K743>
, will take precedence over this option if it is enabled. Decode
output will follow Output Filter rules.
Note:
Although this feature has built in tolerance when one symbol not exactly line up with other
symbols on the image to consider as same row or column, it is best to be used when the image has
single row or column of symbol to decode or output.
Definition:
Global Sorting Options
specifies the sorting that a user wants to apply to the global
matrix or to decoded symbol output.
Serial Cmd:
<
K748,
sort output,row direction,column direction,minimum same-row symbol overlap
height percentage,minimum same-column symbol overlap width percentage
>
N-8-1
Sort Output
Definition:
Allows you to order symbol data output by row or by column.
Serial Cmd:
<
K748,
sort output
,row direction,column direction,minimum same-row symbol overlap
height percentage,minimum same-column symbol overlap width percentage
>
Default:
0 = Disabled
Options:
0 = Disabled
1 = By Row
2 = By Column
N-8-2
Row Direction
Definition:
Allows you to determine which direction decoded symbol data should be output in a row setup.
Serial Cmd:
<
K748,
sort output,
row direction
,column direction,minimum same-row symbol overlap
height percentage,minimum same-column symbol overlap width percentage
>
Default:
0 = Left to Right
Options:
0 = Left to Right
1 = Right to Left
N-8-3
Column Direction
Definition:
Allows you to determine which direction decoded symbol data should be output in a
column setup.
Serial Cmd:
<
K748,
sort output,row direction,
column direction
,minimum same-row symbol overlap
height percentage,minimum same-column symbol overlap width percentage
>
Default:
0 = Top to Bottom
Options:
0 = Top to Bottom
1 = Bottom to Top
N-8-4
Minimum Same-Row Symbol Overlap Height Percentage
Definition:
Allows you to determine the minimum percentage of overlap at which two symbols are
considered to be on the same row.
Serial Cmd:
<
K748,
sort output,row direction,column direction,
minimum same-row symbol overlap
height percentage
,minimum same-column symbol overlap width percentage
>
Default:
20
Options:
Any number from 0 to 100 (0 = 0% and 100 = 100%)
Symbol
B
is part of
R1
if
Minimum Same-Row Symbol
Overlap Height Percentage
is set to
20
.
Example:
Summary of Contents for V440-F
Page 1: ...Z452 E 01 84 9000440 02 Rev A V440 F C Mount Code Reader User Manual...
Page 31: ...1 Overview of WebLink Interface 1 16 V440 F C Mount Code Reader User Manual...
Page 139: ...4 Setup 4 76 V440 F C Mount Code Reader User Manual...
Page 183: ...7 Terminal 7 6 V440 F C Mount Code Reader User Manual...
Page 243: ...Appendices A 22 V440 F C Mount Code Reader User Manual...
Page 249: ...Appendices C 4 V440 F C Mount Code Reader User Manual...
Page 283: ...Appendices E 10 V440 F C Mount Code Reader User Manual...
Page 399: ...Appendices I 18 V440 F C Mount Code Reader User Manual...
Page 423: ...Appendices K 14 V440 F C Mount Code Reader User Manual...
Page 437: ...Appendices L 14 V440 F C Mount Code Reader User Manual...
Page 471: ...Appendices N 18 V440 F C Mount Code Reader User Manual...
Page 481: ...Appendices O 10 V440 F C Mount Code Reader User Manual...
Page 493: ...Appendices R 8 V440 F C Mount Code Reader User Manual...