H-27
Appendices
V440-F C-Mount Code Reader User Manual
H-1
1 ISO/IEC 29158 Sym
b
o
l Qualit
y Ou
tp
ut 1
H
H-
7-4
D
ecode
s
per
Tr
igger
Thr
eshold
Cell Contrast Threshold
Cell Moduration
Cell Moduration Threshold
Fixed Pattern Damage
Usage:
Sets the threshold for driving the output.
Definition:
Conforms to ISO/IEC 29158 symbol quality grading (A,B,C,D).
Serial Cmd:
<
K890,
output on overall grade, overall grade threshold, cell contrast,
cell
contrast threshold,
cell modulation, cell modulation threshold, fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Default:
Grade B
Options:
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, drives
Output
if grade is under
Cell Moduration Threshold.
Serial Cmd:
<
K890,
output on overall grade, overall grade threshold, cell contrast, cell
contrast threshold,
cell modulation,
cell modulation threshold, fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Sets the threshold for driving the output.
Definition:
Conforms to ISO/IEC 29158 symbol quality grading (A,B,C,D).
Serial Cmd:
<
K890,
output on overall grade, overall grade threshold, cell contrast, cell
contrast threshold, cell modulation,
cell modulation threshold,
fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Default:
Grade B
Options:
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, drives
Output
if grade is under
Fixed Pattern Damage
Threshold.
Serial Cmd:
<
K890,
output on overall grade, overall grade threshold, cell contrast, cell
contrast threshold, cell modulation,
cell modulation threshold,
fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Summary of Contents for V440-F
Page 1: ...Z452 E 01 84 9000440 02 Rev A V440 F C Mount Code Reader User Manual...
Page 31: ...1 Overview of WebLink Interface 1 16 V440 F C Mount Code Reader User Manual...
Page 139: ...4 Setup 4 76 V440 F C Mount Code Reader User Manual...
Page 183: ...7 Terminal 7 6 V440 F C Mount Code Reader User Manual...
Page 243: ...Appendices A 22 V440 F C Mount Code Reader User Manual...
Page 249: ...Appendices C 4 V440 F C Mount Code Reader User Manual...
Page 283: ...Appendices E 10 V440 F C Mount Code Reader User Manual...
Page 399: ...Appendices I 18 V440 F C Mount Code Reader User Manual...
Page 423: ...Appendices K 14 V440 F C Mount Code Reader User Manual...
Page 437: ...Appendices L 14 V440 F C Mount Code Reader User Manual...
Page 471: ...Appendices N 18 V440 F C Mount Code Reader User Manual...
Page 481: ...Appendices O 10 V440 F C Mount Code Reader User Manual...
Page 493: ...Appendices R 8 V440 F C Mount Code Reader User Manual...
Page 499: ...Appendices S 6 V440 F C Mount Code Reader User Manual...