R-3
Appendices
V440-F C-Mount Code Reader User Manual
R
How to access a RAM
drive from a PC?
A PC can access a RAM drive using the FTP client tool.
The initial values of V440-F are as follows.
Example: When using Internet Explorer to access.
1. If the IP address is the default, enter
ftp://192.168.188.2/imagesd 0/images/
in the address bar to connect.
2. Enter your account and password.
3. Download the file saved in the RAM drive to your PC.
Parallel communications
timing chart
The parallel output signals, OUTPUT1/OUTPUT2/OUTPUT3, can change those roles by the output condition settings.
The default is that those are turned on when all are No-Read.
WebLink - Gear icon -
Advanced
-
I/O
-
OUTPUT1 parameters
-
Output On
Additionally, a timing to turn off can also be adjusted using the following setting.
WebLink - Gear icon -
Advanced
-
I/O
-
OUTPUT1parameters
-
Output Mode
When you want to detect a timing that the output is changed, set the output condition for one of
OUTPUT1/OUTPUT2/OUTPUT3 to
In Read Cycle
.
According to the setting, it turns on in a period from detecting a trigger, reading, and end of output.
For example, the following describes a timing chart in a case of a setting below.
• Output On
OUTPUT1 In Read Cycle
OUTPUT2 Match or Good Read
OUTPUT3 Mismatch or No-Read
• Timing chart
How to estimate an
exposure time when
reading a moving
symbol?
A moving amount of a symbol during exposure should be 1/10 or less of the cell size (for barcode, narrow bar width).
When a cell size is C [mm] and a line speed is L [mm/s], use the following formula to get the exposure time S.
S
≤
0.1×C/L
For example, When a cell size is 0.3 [mm] and a line speed is 300 [mm/s], the exposure time should be 100 [
μ
s] or less.
0.1×0.3 [mm]/300 [mm/s] = 100 [
μ
s]
Settings
Value
IP address
192.168.188.2
Path
imagesd0/images/
Account
target
Password
password
ON
OFF
ON
OFF
ON
OFF
ON
OFF
<Output Mode: Pulse case>
TRIG
OUTPUT1
(In Read Cycle)
OUTPUT2
(Good Read)
OUTPUT3
(Good Read)
In Read Cycle
Pulse Width
setting time: ON
On Good Read
No Reads
These are almost simultaneous, however, In Read Cycle
is going to be turned OFF after starting the results output.
Pulse Width
setting time: ON
In Read Cycle
ON
OFF
ON
OFF
ON
OFF
ON
OFF
<Output Mode: Latch Mode 2 (Status held) case>
TRIG
OUTPUT1
(In Read Cycle)
OUTPUT2
(Good Read)
OUTPUT3
(No Read)
In Read Cycle
In Read Cycle
On Good Read
No Reads
These are almost simultaneous, however, In Read Cycle
is going to be turned OFF after starting the results output.
ON status is held until No Read occurs.
ON status is held until No Read occurs.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
<Output Mode: Latch Mode 3 (OFF at In Read Cycle started) case>
TRIG
OUTPUT1
(In Read Cycle)
OUTPUT2
(Good Read)
OUTPUT3
(No Read)
On Good Read
No Reads
These are almost simultaneous, however, In Read Cycle
is going to be turned OFF after starting the results output.
In Read Cycle
In Read Cycle
ON status is held until In
Read Cycle is started.
ON status is held until In
Read Cycle is started.
Summary of Contents for V440-F
Page 1: ...Z452 E 01 84 9000440 02 Rev A V440 F C Mount Code Reader User Manual...
Page 31: ...1 Overview of WebLink Interface 1 16 V440 F C Mount Code Reader User Manual...
Page 139: ...4 Setup 4 76 V440 F C Mount Code Reader User Manual...
Page 183: ...7 Terminal 7 6 V440 F C Mount Code Reader User Manual...
Page 243: ...Appendices A 22 V440 F C Mount Code Reader User Manual...
Page 249: ...Appendices C 4 V440 F C Mount Code Reader User Manual...
Page 283: ...Appendices E 10 V440 F C Mount Code Reader User Manual...
Page 399: ...Appendices I 18 V440 F C Mount Code Reader User Manual...
Page 423: ...Appendices K 14 V440 F C Mount Code Reader User Manual...
Page 437: ...Appendices L 14 V440 F C Mount Code Reader User Manual...
Page 471: ...Appendices N 18 V440 F C Mount Code Reader User Manual...
Page 481: ...Appendices O 10 V440 F C Mount Code Reader User Manual...
Page 493: ...Appendices R 8 V440 F C Mount Code Reader User Manual...
Page 499: ...Appendices S 6 V440 F C Mount Code Reader User Manual...