2-5
2 Quick Start
V440-F C-Mount Code Reader User Manual
2
-2 Pos
ition
th
e Read
er and
Set
Up Opt
ics
2
2
-2-1
Determining the Optical Setup
Step 4: Based on ideal field of view, use the Field of View / Working Distance charts below to choose the
best lens and camera standoff distance combination that most closely matches the application requirements.
Example:
Read a 2D, 7.5 mil code.
From the guidelines we can determine that
3.5 PPE
is a good starting point.
From the
PPE
to
FOV table
above, we see the ideal field of view for achieving a
PPE
of
3.5
on a
7.5 mil code
is
133.8 mm
.
From the table below, we see there are multiple lens options and working distance options that come close
*
.
• Option 1:
F = 9 mm, Working Distance = 150.
• Option 2:
F = 12.5 mm, Working Distance = 200.
• Option 3:
F = 16 mm, Working Distance = 250.
*Note:
Please note that it normal to interpolate between the set working distances in the chart to come up with
the best answer. ALWAYS TEST the solution on your exact samples. You can always move the camera in to
increase the resolution.
Field of View for 25* to 500 mm Working Distance
Field of View at 600 to 2500 mm Working Distance
Important:
See
.
Field of View (mm x mm) at Specific Working Distances (mm)
Lens FL
25
50
75
100
150
200
250
300
350
400
450
500
F = 6
35 x 30
71 x 59
106 x 89
142 x 118 213 x 177 283 x 236 354 x 296 425 x 355 496 x 414 567 x 473 638 x 532 708 x 591
F = 8
27 x 22
53 x 44
80 x 66
106 x 89
159 x 133 213 x 177 266 x 222 319 x 266 372 x 310 425 x 355 478 x 399 531 x 443
F = 9
24 x 20
47 x 39
71 x 59
94 x 79
142 x 118 189 x 158 236 x 197 283 x 236 331 x 276 378 x 315 425 x 355 472 x 394
F = 12.5
17 x 14
34 x 28
51 x 43
68 x 57
102 x 85
136 x 113 170 x 142 204 x 170 238 x 199 272 x 227 306 x 255 340 x 284
F = 16
13 x 11
27 x 22
40 x 33
53 x 44
80 x 66
106 x 89
133 x 111 159 x 133 186 x 155 213 x 177 239 x 199 266 x 222
F = 25
9 x 7
17 x 14
26 x 21
34 x 28
51 x 43
68 x 57
85 x 71
102 x 85
119 x 99
136 x 113 153 x 128 170 x 142
F = 35
6 x 5
12 x 10
18 x 15
24 x 20
36 x 30
49 x 41
61 x 51
73 x 61
85 x 71
97 x 81
109 x 91
121 x 101
F = 50
4 x 4
9 x 7
13 x 11
17 x 14
26 x 21
34 x 28
43 x 35
51 x 43
60 x 50
68 x 57
77 x 64
85 x 71
F = 75
3 x 2
6 x 5
9 x 7
11 x 9
17 x 14
23 x 19
28 x 24
34 x 28
40 x 33
45 x 38
51 x 43
57 x 47
F = 100
2 x 2
4 x 4
6 x 5
9 x 7
13 x 11
17 x 14
21 x 18
26 x 21
30 x 25
34 x 28
38 x 32
43 x 35
*
For working distances shorter than the minimum working distance specified for the lens, an extension ring is required to focus the lens.
Field of View (mm x mm) at Specific Working Distances (mm)
Lens FL
600
700
800
900
1000
1250
1500
1750
2000
2500
F = 6
850 x 709
992 x 828
1133 x 946
1275 x 1064 1417 x 1182 1771 x 1478 2125 x 1773 2479 x 2069 2833 x 2364 3542 x 2956
F = 8
638 x 532
744 x 621
850 x 709
956 x 798
1063 x 887
1328 x 1108 1594 x 1330 1859 x 1552 2125 x 1773 2656 x 2217
F = 9
567 x 473
661 x 552
756 x 631
850 x 709
944 x 788
1181 x 985
1417 x 1182 1653 x 1379 1889 x 1576 2361 x 1970
F = 12.5
408 x 340
476 x 397
544 x 454
612 x 511
680 x 567
850 x 709
1020 x 851
1190 x 993
1360 x 1135 1700 x 1419
F = 16
319 x 266
372 x 310
425 x 355
478 x 399
531 x 443
664 x 554
797 x 665
930 x 776
1063 x 887
1328 x 1108
F = 25
204 x 170
238 x 199
272 x 227
306 x 255
340 x 284
425 x 355
510 x 426
595 x 497
680 x 567
850 x 709
F = 35
146 x 122
170 x 142
194 x 162
219 x 182
243 x 203
304 x 253
364 x 304
425 x 355
486 x 405
607 x 507
F = 50
102 x 85
119 x 99
136 x 113
153 x 128
170 x 142
213 x 177
255 x 213
298 x 248
340 x 284
425 x 355
F = 75
68 x 57
79 x 66
91 x 76
102 x 85
113 x 95
142 x 118
170 x 142
198 x 166
227 x 189
283 x 236
F = 100
51 x 43
60 x 50
68 x 57
77 x 64
85 x 71
106 x 89
128 x 106
149 x 124
170 x 142
213 x 177
General lens formulas for any combination, given working
distance, focal length, or field of view width:
Field of View Width =
8.5 x Working Distance / Focal Length
Field of View Height =
7.093 x Working Distance / Focal Length
Focal Length =
8.5 x Working Distance / Field of View Width
Working Distance =
Field of View Width x Focal Length / 8.5
Summary of Contents for V440-F
Page 1: ...Z452 E 01 84 9000440 02 Rev A V440 F C Mount Code Reader User Manual...
Page 31: ...1 Overview of WebLink Interface 1 16 V440 F C Mount Code Reader User Manual...
Page 139: ...4 Setup 4 76 V440 F C Mount Code Reader User Manual...
Page 183: ...7 Terminal 7 6 V440 F C Mount Code Reader User Manual...
Page 243: ...Appendices A 22 V440 F C Mount Code Reader User Manual...
Page 249: ...Appendices C 4 V440 F C Mount Code Reader User Manual...
Page 283: ...Appendices E 10 V440 F C Mount Code Reader User Manual...
Page 399: ...Appendices I 18 V440 F C Mount Code Reader User Manual...
Page 423: ...Appendices K 14 V440 F C Mount Code Reader User Manual...
Page 437: ...Appendices L 14 V440 F C Mount Code Reader User Manual...
Page 471: ...Appendices N 18 V440 F C Mount Code Reader User Manual...
Page 481: ...Appendices O 10 V440 F C Mount Code Reader User Manual...
Page 493: ...Appendices R 8 V440 F C Mount Code Reader User Manual...
Page 499: ...Appendices S 6 V440 F C Mount Code Reader User Manual...