4 Setup
4-26
V440-F C-Mount Code Reader User Manual
The decoded data and decode time is shown for each code. The decoded data shows if decodes are
successful for each cell. The decode time allows you to determine if there are any issues with uniformity of
lighting across the image. Each code should have roughly the same decode time in a well-illuminated image.
The
Rate
report window on the right side of the screen displays image
Capture
time, as well as the
Decode
time and
Total Read
time for all search areas. The Rate view also displays the
Overhead
and
Trigger Rate
values.
The
Matrix Info
window shows decode timing statistics for reading all symbols within the grid, including
how many codes were found.
The sorted string which is
top-left
to
bottom-right
by default is shown in the
Output Data
window.
4-6-2
On-Screen Reporting
Summary of Contents for V440-F
Page 1: ...Z452 E 01 84 9000440 02 Rev A V440 F C Mount Code Reader User Manual...
Page 31: ...1 Overview of WebLink Interface 1 16 V440 F C Mount Code Reader User Manual...
Page 139: ...4 Setup 4 76 V440 F C Mount Code Reader User Manual...
Page 183: ...7 Terminal 7 6 V440 F C Mount Code Reader User Manual...
Page 243: ...Appendices A 22 V440 F C Mount Code Reader User Manual...
Page 249: ...Appendices C 4 V440 F C Mount Code Reader User Manual...
Page 283: ...Appendices E 10 V440 F C Mount Code Reader User Manual...
Page 399: ...Appendices I 18 V440 F C Mount Code Reader User Manual...
Page 423: ...Appendices K 14 V440 F C Mount Code Reader User Manual...
Page 437: ...Appendices L 14 V440 F C Mount Code Reader User Manual...
Page 471: ...Appendices N 18 V440 F C Mount Code Reader User Manual...
Page 481: ...Appendices O 10 V440 F C Mount Code Reader User Manual...
Page 493: ...Appendices R 8 V440 F C Mount Code Reader User Manual...
Page 499: ...Appendices S 6 V440 F C Mount Code Reader User Manual...