background image

manhattanproducts.com

MH-178495_UM-0418_REV-5.01

Wireless Linear CCD 

Barcode Scanner

 

Programming Guide

Model 178495

Summary of Contents for 178495

Page 1: ...manhattanproducts com MH 178495_UM 0418_REV 5 01 Wireless Linear CCD Barcode Scanner Programming Guide Model 178495 ...

Page 2: ...differ Manhattan reserves the right to make changes to any software or hardware to improve reliability function or design at any time without notice The information contained herein is subject to change without prior notice No user corporation or individual shall duplicate in whole or in part distribute modify decompile disassemble decode reverse engineer rent transfer or sublicense such software ...

Page 3: ...rameters 13 Output Characters Parameters 15 Wand Emulation Mode Parameters 16 Chapter 7 Barcode Types 17 Symbologies Selection 17 UPC EAN Jan Parameters 20 Code 39 Parameters 23 Code 128 Parameters 24 Interleave 25 Parameters 26 Industrial Parameters 27 Matrix 25 Parameters 29 Codabar NW7 Parameters 30 Code 93 Parameters 31 Code 11 Parameters 32 MSI Plessey Code Parameters 34 Code 2 of 6 Parameter...

Page 4: ...e host Note Find and maintain the right reading distance from the same types of barcodes to increase scanning success Scanner Parameters Physical Parameters Parameter Value Weight Scanner Cradle 0 2 kg 0 44 lbs 0 1 kg 0 22 lbs Device Dimensions Scanner Cradle 18 3 x 9 x 7 cm 7 x 3 5 x 2 76 in 19 x 9 5 x 4 cm 7 5 x 3 7 x 1 6 in Material ABS and rubber Color Black Interface RJ45 to RS232 Wireless Sc...

Page 5: ...ack to the Default Settings scan the Set All Defaults barcode Factory Defaults Custom Settings The factory default settings are shown with in the following sections Users can create customized settings by following the procedures described in later chapters To save settings perma nently scan the barcode called Save Parameters otherwise the settings will not be saved after the decoder is powered of...

Page 6: ... cradle 2 Connect the power adapter from a power source to the input jack into the cradle 3 Turn on your computer Pair the Cradle to the Scanner If paired the cradle sends scanned data to the computer via cable When the scanner begins the pairing process it beeps three short times A blue LED blinks and a long beep will follow The blue LED flashes slowly The connection process is complete in about ...

Page 7: ... of the methods described below to pair your device Emulating a Serial Connection 1 Scan the Start Configuration barcode above 2 Scan the SPP Replica barcode below 3 When prompted enter the pin default 00 00 00 4 When pairing is successful the blue LED blinks and is followed by a long beep The blue LED flashes slowly while it finishes setup 5 Scan the End Configuration barcode above SPP Replica Mo...

Page 8: ...will be saved permanently Recall Stored Parameters Replace the current parameters by the parameters you saved last time Set All Defaults Set all the parameters to the factory default settings Start Configuration Enter the configuration mode End Configuration Exit the configuration mode Abort Configuration Terminate current programming status Version Information Display the decoder version informat...

Page 9: ...is function allows the scanner to retain barcode data in the scanner s memory for uploading at a convenient time Up to 30 000 barcodes EAN13 size can be stored Enable Disable Upload Data Delete Data Delete Last Scan Out of Range Function This function allows the scanner to retain barcode data when it is out of scanning range It will upload the data once it reconnects Enable Disable ...

Page 10: ...OFF 02 71 Trigger ON OFF 02 70 Continuous Trigger OFF 02 72 Testing 02 75 Continuous Auto Power On 02 73 Flash 02 74 Flash Auto Power On 02 76 Reserved 1 02 77 Reserved 2 09 F8 Reserved 3 09 F9 Reserved 4 09 FA Reserved 5 09 FB Reading Selection Mode ...

Page 11: ...Communication Parameters Set up Baud Rate 600 0Y70 1200 0Y71 2400 0Y72 4800 0Y73 9600 0Y77 19200 0Y74 38400 0Y75 Set up Data Bits 7 Data Bits 0Y80 8 Data Bits 0Y88 Set up Stop Bits 1 Bit 0YO8 2 Bits 0YO0 Serial Mode Parameters ...

Page 12: ...D Barcode Scanner Set Up Parity 0YN7 None 0YN3 Odd 0YN2 Even 0YN1 Mark 0YN0 Space Handshaking 018 8 RTS CTS Enable 018 0 RTS CTS Disable 014 4 ACK NAK Enable 014 0 ACK NAK Disable 03K 4 XON XOFF Enable 03K 0 XON OFF Disable ...

Page 13: ...nal Type IBM PC AT PS 2 0ZF0 IBM PC XT 0ZF1 IBM PS 2 25 30 0ZF2 NEC 9800 0ZF3 Apple Desktop Bus ADB 0ZF4 IBM 5500 0ZF5 IBM 122 Key 1 0ZF6 IBM 102 Key 0ZF7 IBM 122 Key 2 0ZF8 Reserved 1 0ZF9 Reserved 2 0ZFA Reserved 3 0ZFB Reserved 4 0ZFC Reserved 5 0ZFD ...

Page 14: ...inear CCD Barcode Scanner Upper Lower Case No Change 0330 Upper Case 0331 Lower Case 0332 Send Character by ALT Method Enable 03O8 Disable 03O0 Select Numerical Pad ON 01K4 OFF 01K0 Capslock Detection Enable Disable ...

Page 15: ...User Manual 15 Select Terminator Output Characters Parameters CR LF 7S2 None 7S7 CR 7S0 LF 7S1 Space 7S4 HT TAB 7S3 STX ETX 7S5 Time out Between Characters 0 ms 5 ms 10 ms 25 ms 0070 0071 0072 0073 ...

Page 16: ...0076 300 ms 0077 Wand Emulation Mode Parameters TTL Level Representation Scan Speed Selection Output Format Selection Bar Equals High 02K4 Bar Equals Low 02K0 Fast 0288 Slow 0280 Output as Code 39 02O8 Output as Code 39 Full ASCII 02O0 Output as Original Code Format 0XK4 ...

Page 17: ...arcode Types Symbologies Selection UPC A ON 0074 OFF 0A40 UPC E ON 0BO8 OFF 0BO0 OFF 0A20 OFF 0A10 OFF 0EO0 OFF 0FO0 OFF 0JO0 EAN 13 JAN 13 ISBN13 ON 0A22 EAN 8 JAN 8 ON 0A11 CODE 39 ON 0EO8 CODE 128 ON 0FO8 CODABAR NW7 ON 0JO8 ...

Page 18: ... CCD Barcode Scanner Interleave 25 ON 0GO8 Industrial 25 ON 0HO8 Matrix 25 ON 0IO8 CODE 93 ON 0KO8 CODE 11 ON 0LO8 China Postage ON 0MO8 MSI PLESSEY ON 0NO8 0GO0 OFF 0HO0 OFF 0IO0 OFF 0KO0 OFF 0LO0 OFF 0MO0 OFF 0NO0 OFF ...

Page 19: ...User Manual 19 CODE 93 ON 0PO8 0PO0 OFF 0TO0 OFF 0TO8 Telepen ON 0QO8 Reserved4 ON 0RO8 Reserved5 ON 0SO8 Reserved6 ON 0QO0 OFF 0RO0 OFF 0SO0 OFF LDC25 ON 0QO8 OFF 0QO0 ...

Page 20: ...14 ON 0UO8 RSS 14 OFF 0UO0 RSS Limit ON 0VO8 RSS Limit OFF 0VO0 RSS Expanded ON 0WO8 RSS Expanded OFF 0WO0 Select All Bar Codes 1A UPC EAN Jan Parameters Reading Type UPCA EAN13 ON 0AK4 UPCA EAN13 OFF 0AK0 ISBN 10 Enable 0B88 ISBN 13 Enable 0B80 ...

Page 21: ...code with Supplement 01O0 Autodiscriminate Supplement 01O8 UPC E Enable 0BH1 UPC E Disable 0BH0 EAN8 EAN13 Enable 0A08 EAN8 EAN13 Disable 0AO0 GTIN Format Enable 0X44 GTIN Format Disable 0X40 Supplemental Set Up 0B33 No Transmission 0B31 Transmit 2 Code ...

Page 22: ...0B30 Transmit 2 5 Code Transmission ON 0A12 UPC A Check Digit OFF 0A10 Transmission ON UPC E Check Digit 0B12 OFF 0B10 Transmission ON EAN 8 Check Digit 0A88 OFF 0A80 Transmission ON EAN 13 Check Digit 0AH1 OFF 0AH0 Transmission ON ISSN Check Digit 0BK4 OFF 0BK0 ...

Page 23: ...ian Pharmacy Code 32 OFF 0E88 Italian Pharmacy Code 32 OFF Check Digit Transmission 0EM2 Do Not Calculate Check Digit 0EM6 Calculate Check Digit Transmit 0EM4 Calculate Check Digit but Do Not Transmit Enable 0E44 Disable 0E40 Output Start Stop Character Decode Asterisk Enable 0E22 Disable 0E20 ...

Page 24: ...the barcode containing Complete for the desired set Repeat steps one through three to set additional lengths Set Up Code Length Minimum Length 1 Begin 2 2 Scan Decimal Value Appendix A 2C0 3 Complete Fix Length Two Sets Available 1 Begin 1st Set 4E00 2 Scan Decimal Value Appendix A 3 Complete 1st Set 4E01 2 Scan Decimal Value Appendix A 3 Complete 2nd Set 4E02 1 Begin 2nd Set 4E00 Code 128 Paramet...

Page 25: ...d length 1 Scan the barcode containing Begin for the desired set 2 Refer to the Decimal Value Tables in Appendix A Scan the label s that represent the length to be read 3 Scan the barcode containing Complete for the desired set Repeat steps one through three to set additional lengths Set Up Code Length Variable 4F1 Fix Length Two Sets Available 1 Begin 1st Set 4F00 2 Scan Decimal Value Appendix A ...

Page 26: ...al Value Appendix A 3 Complete 2nd Set 4F02 1 Begin 2nd Set 4F00 Interleave 25 Parameters Check DigitTransmission Do Not Calculate Check Digit 0GN3 Calculate Check Digit Transmit 0GN7 Calculate Check Digit but Do Not Transmit 0GN5 Set Up Number of Characters Even 0G88 Odd 0G80 Brazilian Banking Code Disable 0G40 Enable 0G44 ...

Page 27: ...ning Complete for the desired set Repeat steps one through three to set additional lengths Set Up Code Length Fix Length Two Sets Available 1 Begin 1st Set 4G00 2 Scan Decimal Value Appendix A 3 Complete 1st Set 4F01 4G1 Variable Industrial Parameters Reading Types IATA25 Enable 0H44 0H40 Disable 1 Begin 2nd Set 4G00 2 Scan Decimal Value Appendix A 3 Complete 2nd Set 4G01 Minimum Length 1 Begin 2 ...

Page 28: ...he Decimal Value Tables in Appendix A Scan the label s that represent the length to be read 3 Scan the barcode containing Complete for the desired set Repeat steps one through three to set additional lengths Set Up Code Length Fix Length Two Sets Available 1 Begin 1st Set 4G00 2 Scan Decimal Value Appendix A 3 Complete 1st Set 4F01 4G1 Variable 2 Scan Decimal Value Appendix A 1 Begin 2nd Set 4G00 ...

Page 29: ...the steps below to set a fixed length 1 Scan the barcode containing Begin for the desired set 2 Refer to the Decimal Value Tables in Appendix A Scan the label s that represent the length to be read 3 Scan the barcode containing Complete for the desired set Repeat steps one through three to set additional lengths Set Up Code Length 4I1 Variable 2 Scan Decimal Value Appendix A 1 Begin 2nd Set 4I00 3...

Page 30: ... Linear CCD Barcode Scanner Codabar NW7 Parameters Set Up Start Stop upon Transmission ON OFF Transmission Type of Start Stop A B C D Start A B C D Stop A Start A Stop B Start B Stop C Start C Stop D Start D Stop ...

Page 31: ...set Repeat steps one through three to set additional lengths Set Up Code Length 4J1 Variable Fix Length Two Sets Available 1 Begin 1st Set 4J00 2 Scan Decimal Value Appendix A 3 Complete 1st Set 4J01 2 Scan Decimal Value Appendix A 1 Begin 2nd Set 4J00 3 Complete 2nd Set 4J02 2C5 Minimum Length 2 Scan Decimal Value Appendix A 1 Begin 2 3 Complete Code 93 Parameters Check Digit Transmission Calcula...

Page 32: ...for the desired set Repeat steps one through three to set additional lengths Set Up Code Length 4K1 Variable Fix Length Two Sets Available 2 Scan Decimal Value Appendix A 1 Begin 1st Set 4K00 3 Complete 1st Set 4K01 1 Begin 2nd Set 4K00 2 Scan Decimal Value Appendix A 3 Complete 2nd Set 4K02 Minimum Length 1 Begin 2 2 Scan Decimal Value Appendix A 3 Complete 2C6 Code 11 Parameters Check Digit Tran...

Page 33: ...eat steps one through three to set additional lengths Set Up Code Length 4L1 Variable Fix Length Two Sets Available 1 Begin 1st Set 4L00 2 Scan Decimal Value Appendix A 3 Complete 1st Set 4L01 2 Scan Decimal Value Appendix A 1 Begin 2nd Set 4L00 3 Complete 2nd Set 4L02 Minimum Length 2 Scan Decimal Value Appendix A 1 Begin 2 3 Complete 2C7 Calculate Check 1 Digit but Do Not Transmit Calculate Chec...

Page 34: ...t 2 Refer to the Decimal Value Tables in Appendix A Scan the label s that represent the length to be read 3 Scan the barcode containing Complete for the desired set Repeat steps one through three to set additional lengths Set Up Code Length 4N1 Variable Fix Length Two Sets Available 1 Begin 1st Set 4N00 2 Scan Decimal Value Appendix A 3 Complete 1st Set 4N01 2 Scan Decimal Value Appendix A 1 Begin...

Page 35: ...ne through three to set additional lengths Set Up Code Length Do Not Calculate Check Digit 0PN3 Calculate Check Digit Transmit 0PN7 Calculate Check Digit but Do Not Transmit 0PN5 Code 2 of 6 Parameters Check Digit Transmission 0P1 Variable Fix Length Two Sets Available 1 Begin 1st Set 4P00 2 Scan Decimal Value Appendix A 3 Complete 1st Set 4P01 2 Scan Decimal Value Appendix A 1 Begin 2nd Set 4P00 ...

Page 36: ...gth 1 Scan the barcode containing Begin for the desired set 2 Refer to the Decimal Value Tables in Appendix A Scan the label s that represent the length to be read 3 Scan the barcode containing Complete for the desired set Repeat steps one through three to set additional lengths Set Up Code Length 4T1 Variable Fix Length Two Sets Available 1 Begin 1st Set 4T00 2 Scan Decimal Value Appendix A 3 Com...

Page 37: ... Check Digit 0VN7 0VN5 Transmit RSS Limit Application ID 0V88 Do Not Transmit RSS Limit Application ID 0V80 GS1 Data bar RSS 14 Parameters Do Not Transmit RSS 14 Check Digit 0UN5 Transmit RSS 14 Check Digit 0UN7 Transmit RSS 14 Application ID 0U88 Do Not Transmit RSS 14 Application ID 0U80 Transmit RSS 14 Symbology ID 0U44 Do Not Transmit RSS 14 Symbology ID 0U40 ...

Page 38: ...near CCD Barcode Scanner RSS Expanded Parameters Transmit RSS Limit Symbology ID 0V44 Do Not Transmit RSS Limit Symbology ID 0V40 Transmit RSS Expanded Symbology ID 0W44 Do Not Transmit RSS Expanded Symbology ID 0W44 ...

Page 39: ...er Manual 39 Chapter 8 Miscellaneous Parameters Language Selection US English 0ZV0 UK English 0ZV1 Italiano 0ZV2 Español 0ZV3 Français 0ZV4 Deutsch 0ZV5 Svenska 0ZV6 Suisse 0ZV7 Magyar 0ZV8 Japanese 0ZV9 ...

Page 40: ...to the output barcode string when a code is scanned The following table shosw barcode type by ID Code Type ID Code Type ID UPC A A UPC E B EAN 8 C EAN 13 D CODE 39 E CODE 128 F Interleave 25 G Industrial 25 H Matrix 25 I Codabar NW7 J CODE 93 K CODE 11 L China Postage M MSI PLESSEY N Code 2 of 6 P LCD25 Q Telepen T RSS 14 U RSS Limit V RSS Expanded W Barcode ID ON 00H1 OFF 00H0 Default 913 Default...

Page 41: ...resents the desired code ID NOTE A user defined code ID will override a default value The system will not check for conflicts with other assigned codes It is possible to have more than two symbologies that have the same code ID UPC A 91A UPC E 91B EAN 13 JAN 13 91Y EAN 8 JAN 8 91Z CODE 39 91E CODE 128 91F CODABAR NW7 91J Industrial 25 91H Interleave 25 91G Matrix 25 91I ...

Page 42: ...ess Linear CCD Barcode Scanner CODE 93 91K China Postage 91M BC412 91O CODE 11 91L MSI PLESSEY 91N CODE 2 of 6 91P Telepen 91T LCD 25 91Q RSS 14 91U RSS Limit 91V RSS Expanded 91W Reserved 5 91R Reserved 6 91S ...

Page 43: ...s High 03I2 Bar Equals Low 0310 Reading Level One Time 0130 Two Times 0131 Three Times 0132 Four Times 0133 Accuracy High 01J3 Medium 01J2 Low 01J1 Off 01J0 Buzzer Tone LED ON 09O8 LED OFF 09O0 Indicator LED ON OFF SV700 only ...

Page 44: ...1 to 50 3 Scan the Complete barcode To Set Up Timeouts 1 Begin 2 Scan Decimal Value 1 50 Appendix A 3000 03001 3 Complete Same Symbol Timeout In Continuous Flash reading mode this function sets a delay for rescanning a barcode that is still in the scan field Users can define values from 1 50 100 ms to 5 seconds respectively graded in 100 ms increments default is 3 0 3s Disable 0340 Enable 0344 Not...

Page 45: ...present s the desired position to be deleted 4 Scan the Complete barcode in the section titled Character Position to Be Deleted below 5 In Appendix A scan the barcode that represents the number of characters to be deleted 6 Scan the Complete barcode in the section titled Number of Characters to be Deleted below To Set Up Deletion of Output Characters First Set 800 Second Set 801 Fourth Set 803 Fif...

Page 46: ...s Linear CCD Barcode Scanner EAN 13 JAN 13 81Y EAN 8 JAN 8 81Z CODE 39 81E CODE 128 81F CODABAR NW7 81J Industrial 25 81H Interleave 25 81G Matrix 25 81I CODE 93 81K China Postage 81M CODE 11 81L MSI PLESSEY 81N ...

Page 47: ...of Characters to Be Deleted 1 Decimal Value Appendix A 2 Complete 830 Setup Insertion 1 Scan the barcode of the desired set in the section titled Select Insertion Set Number below 2 Scan the barcode for the desired symbology in the section titled Symbologies below 3 Refer to the Decimal Value Tables in Appendix A Scan the barcode s that represent s the desired To Set Up Insertion of Output Charact...

Page 48: ...ix B or the Function Key tables in Appendix C and scan the barcode that represents the desired characters to be inserted 6 Scan the Complete barcode in the section titled Number of Characters to Be Inserted below First Set 500 Second Set 501 Fourth Set 503 Fifth Set 504 Sixth Set 505 Third Set 502 Select Deletion Set Number Symbologies UPC A 51A UPC E 51B EAN 13 JAN 13 51Y EAN 8 JAN 8 51Z ...

Page 49: ...User Manual 49 CODE 39 51E CODE 128 51F CODABAR NW7 51J Industrial 25 51H Interleave 25 51G Matrix 25 51I CODE 93 51K China Postage 51M CODE 11 51L MSI PLESSEY 51N CODE 2 of 6 51P Telepen 51T ...

Page 50: ...ded 51W All Codes 51S None 514 RSS 14 51U RSS Limit 51V 51Q Character Position to Be Inserted 1 Decimal Value Appendix A 2 Complete 520 Characters to Be Inserted 1 Decimal Value Appendix A 2 Complete 530 Disable 0XH0 Set up IR Sensor LG303 only Enable 0XH1 ...

Page 51: ...User Manual 51 Appendix A Decimal Value Table 1 0 2 3 4 5 6 7 8 9 ...

Page 52: ...I Table 65 X T E 03 L L U N 00 K C A 06 T H 09 F F 0C I S 0F 2 C D 12 K A N 15 N A C 18 C S E 1B S R 1E STX 02 ENQ 05 BS 08 VT 0B SO 0E DC1 11 DC4 14 ETB 17 SUB 1A GS 1D H O S 01 T O E 04 L E B 07 F L 0A R C 0D E L D 10 3 C D 13 N Y S 16 M E 19 S F 1C S U ...

Page 53: ...User Manual 53 E C A P S 20 23 26 29 2C 2F 32 35 38 3B 3E 1 4 7 22 25 28 2B 2E 31 34 37 3A 3D 21 24 27 2A 2D 30 33 36 39 3C 3F ...

Page 54: ...54 Wireless Linear CCD Barcode Scanner 40 43 46 49 4C 4F 52 55 58 5B 5E B E H K N Q T W Z 42 45 48 4B 4E 51 54 57 5A 5D 41 44 47 4A 4D 50 53 56 59 5C 5F ...

Page 55: ...User Manual 55 60 63 66 69 6C 6F 72 75 78 7B 7E b e h k n q t w z 62 65 68 6B 6E 71 74 77 7A 7D 61 64 67 6A 6D 70 73 76 79 7C DEL 7F ...

Page 56: ...nner Appendix C Function Key Table 1 F 4 F 7 F 0 1 F t r e s n I p U e g a P t f e L Down C0 C3 C6 C9 CC CF D2 D5 F3 F6 F9 F12 Home End Up C2 C5 C8 CB CE D1 D4 2 F C1 5 F C4 8 F C7 1 1 F CA e t e l e D CD n w o D e g a P D0 t h g i R D3 ...

Page 57: ...ce the current parameters by the parameters you saved last time Set All Defaults Set all the parameters to the factory default settings Start Configuration Enter the configuration mode End Configuration Exit the configuration mode Abort Configuration Terminate current programming status Version Information Display the decoder version information and date code 0 1 2 6 5 4 3 ...

Page 58: ...o simbolo sui prodotto o sulla relativa confezione indica che il prodotto non va trattato come un rifiuto domestico In ottemperanza alla Direttiva UE 2012 19 EU sui rifiuti di apparecchiature elettriche ed elettroniche RAEE questa prodotto elettrico non deve essere smaltito come rifiuto municipale misto Si prega di smaltire il prodotto riportandolo al punto vendita o al punto di raccolta municipal...

Page 59: ...on If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and the receiver connect the equipment to an outlet on a circuit d...

Page 60: ...attanproducts com All trademarks and trade names are the property of their respective owners IC Intracom All rights reserved Manhattan is a trademark of IC Intracom registered in the U S and other countries ...

Reviews: