Page 1: ...Magellan 1400i Omni Directional Imaging Scanner Product Reference Guide ...

Page 2: ...9698 5086879 5115120 5144118 5146463 5179270 5198649 5200597 5202784 5208449 5210397 5212371 5212372 5214270 5229590 5231293 5232185 5233169 5235168 5237161 5237162 5239165 5247161 5256864 5258604 5258699 5260554 5274219 5296689 5298728 5311000 5327451 5329103 5330370 5347113 5347121 5371361 5382783 5386105 5389917 5410108 5420410 5422472 5426507 5438187 5440110 5440111 5446271 5446749 5448050 546...

Page 3: ...x Reporting PIR 2 11 Scanning Features 2 12 Aiming Pointer 2 12 Targeted Scanning Mode 2 12 Wake Up Intensity 2 15 Interface Selection 3 3 Interface Features 3 7 RS 232 Interface Features 3 9 ACK NAK Error Handling 3 23 IBM USB Interface Features 3 24 IBM 3 25 Wand Emulation 3 26 Keyboard Wedge 3 30 USB Keyboard 3 30 Data Editing Overview 4 1 Please Keep In Mind 4 1 Global Prefix Suffix 4 2 AIM ID...

Page 4: ... RSS Limited 5 24 Disable Enable RSS Limited 5 24 RSS Limited UCC EAN 128 Emulation 5 25 Minimum Reads 5 25 RSS Limited 2D Component 5 26 Code 39 5 27 Disable Enable Code 39 5 27 Check Character Calculation 5 27 Check Character Transmit 5 28 Start Stop Characters 5 28 Code 39 Full ASCII 5 29 Length Control 5 30 Code 39 Length 1 Length 2 Programming Instructions 5 31 Quiet Zones 5 31 Code 39 Stitch...

Page 5: ... MSI Plessey Length 1 Length 2 Programming Instructions 5 60 MSI Plessey Stitching 5 61 Minimum Reads 5 62 Standard 2 of 5 5 63 Disable Enable Standard 2 of 5 5 63 Check Digit Verification 5 63 Check Digit Transmit 5 64 Length Control 5 65 Standard 2 of 5 Length 1 Length 2 Programming Instructions 5 66 Standard 2 of 5 Stitching 5 67 Minimum Reads 5 68 PDF417 5 69 Disable Enable PDF417 5 69 PDF417 ...

Page 6: ...iv Magellan 1400i Keyboard Wedge B 2 Standard Feature Defaults D 1 Keyboard Model Cross Reference E 1 Accepting RS 232 Commands F 1 ...

Page 7: ...Guide QRG Copies of other publications for this product are downloadable free of charge from the website listed on the back cover of this manual On leaving the factory units are programmed for the most common terminal and communica tions settings If you need to change these settings custom programming can be accomplished by scanning the bar codes in this guide Bold text and a yellow highlighted ba...

Page 8: ...er supply AC Adapter Plug the AC Adapter barrel connector into the socket on the RS 232 cable con nector and the AC Adapter plug into a standard power outlet Figure 1 RS 232 Serial or USB Connection using A C Adapter USB Connection Connect the scanner to a USB port on the terminal PC using the correct USB cable for the interface type you ordered Reference Figure 1 and Figure 2 Figure 2 Other Conne...

Page 9: ... your scanner Some programming bar code labels like the label below for resetting defaults require only the scan of that single label to enact the change Most of the programming labels in this manual however require the scanner to be placed in Programming Mode prior to scanning them Scan a START END bar code once to enterProgramming Mode Once the scanner is in Programming Mode you can scan a numbe...

Page 10: ...t Host Disable Constant green flash at 1 Hz 100mS on 900mS off The scanner is disabled due to receiving a disble command from the POS terminal Diagnostics Varies see Error Codes on page 1 5 for more information The LED can provide diagnostic feedback if the scanner dis covers a problem during SelfTest BEEPER FUNCTIONS BEEPER INDICATION INDICATION COMMENT Power On Beep Single beep The Power On LED ...

Page 11: ...tered FRU1 isolation mode If the scanner is reset or the button is pressed the sequence will be repeated The following table describes the LED flashes beep codes associated with an error found 1 Field Replaceable Unit FRU NUMBER OF LED FLASHES BEEPS ERROR CORRECTIVE ACTION 1 Configuration Contact Helpdesk for assistance 2 Interface PCB 6 Main PCB 10 Button Error 11 Near Field Imager Module 12 Far ...

Page 12: ...Getting Started 1 6 Magellan 1400i NOTES ...

Page 13: ...out The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again e g two identical items in succession START END PROGRAMMING BAR CODES 0 1 Second 0 2 Second 0 3 Second 0 4 Second 0 5 Second 0 6 Second DEFAULT ...

Page 14: ...limit that determines how much time must pass before reading the same PDF417 label again e g two identical PDF417 bar codes in suc cession START END PROGRAMMING BAR CODES 0 7 Second 0 8 Second 0 9 Second 1 Second NOTE This double read timer value is used ONLY when scanning PDF417 bar codes START END PROGRAMMING BAR CODES 1 5 Seconds ...

Page 15: ...ad Timeout Product Reference Guide 2 3 PDF Double Read Timeout cont START END PROGRAMMING BAR CODES 1 6 Seconds 1 8 Seconds DEFAULT 1 9 Seconds 2 Seconds 2 1 Seconds 2 2 Seconds 2 3 Seconds 2 4 Seconds 2 55 Seconds ...

Page 16: ...y three digits zero padded from the Alphanumeric table in Appendix C Alpha Numeric Pad representing the desired time value Exit programming mode by scanning the START END bar code again DEFAULT SETTING FOR THIS FEATURE 200 milliseconds 020 Set Label Gone Timeout START END PROGRAMMING BAR CODES Sets the label gone timeout duration using hex values from 001 to 255 in increments of ten milliseconds 1...

Page 17: ...uide 2 5 Sleep Mode This feature specifies the amount of time with no bar code reads before the scanner enters sleep mode START END PROGRAMMING BAR CODES 15 Seconds DEFAULT 30 Seconds 1 Minute 2 Minutes 3 Minutes 4 Minutes 5 Minutes ...

Page 18: ...General Features 2 6 Magellan 1400i Sleep Mode cont START END PROGRAMMING BAR CODES 6 Minutes 7 Minutes 8 Minutes 9 Minutes 10 Minutes DEFAULT 12 Minutes 15 Minutes 30 Minutes 1 Hour ...

Page 19: ...nce Guide 2 7 LED and Beeper Indicators Power On Alert Disables or enables the indication a single beep that the scanner has finished all its power up tests and is now ready for operation START END PROGRAMMING BAR CODES Disable Enable DEFAULT ...

Page 20: ...ully reading a bar code Choices are Good Read Indicate after decode Good Read Indicate after transmit Good Read Indicate after CTS goes inactive then active NOTE This option Indicate after CTS goes inactive then active which uses CTS is only valid for RS 232 inter faces START END PROGRAMMING BAR CODES After Decode DEFAULT After Transmit After CTS goes inactive then active ...

Page 21: ...eep upon a successful decode of a bar code Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high frequency selectable from the list below Controls the beeper s pitch tone START END PROGRAMMING BAR CODES Disable Enable DEFAULT START END PROGRAMMING BAR CODES Low Medium DEFAULT High 0 0 1 4 0 2 ...

Page 22: ...eneral Features 2 10 Magellan 1400i Good Read Beep Length Specifies the duration of a good read beep START END PROGRAMMING BAR CODES 60msec DEFAULT 80msec 100msec 120msec 140msec 160msec 180msec 200msec ...

Page 23: ...is appended to decoded data before being presented to the POS The PIR feature allows the scanner to provide information to an external computer indicating how easy the label was to read START END PROGRAMMING BAR CODES Low Medium High DEFAULT NOTE This value added feature is a factory programmed option Contact your dealer for information about upgrading your system to include this advanced capabili...

Page 24: ...arget Mode Active Time Target Mode Linger Time START END PROGRAMMING BAR CODES Disable DEFAULT Enable always on NOTE When add ons are enabled and a bar code is being read while in Targeted Mode position the pointer at or near the end of the base label to ensure the scanner will read both the base and add on label Targeted Scanning Mode will read bar codes in any orientation The scanner will return...

Page 25: ...e 2 13 Target Mode Active Time Specifies the time duration the scanner attempts to decode labels while in the targeted mode of operation START END PROGRAMMING BAR CODES Extra Short Duration Short Duration Medium Duration DEFAULT Long Duration ...

Page 26: ... Mode The linger timer starts upon a good read or upon timeout of Target Mode Active Time whichever is earliest A button press at any time will reset the process back to the start NOTE Active Time and Linger Time settings are totally indepen dent from one another During the period Linger Time is active no bar codes can be read no matter what mode the scanner is in START END PROGRAMMING BAR CODES S...

Page 27: ...e Up Intensity This feature indicates the percentage of ambient light change which will trigger the scanner to wake up from Sleep Mode Lower settings provide greater sensitivity START END PROGRAMMING BAR CODES 5 8 10 DEFAULT 15 20 25 30 35 0 3 B 8 1 9 ...

Page 28: ...General Features 2 16 Magellan 1400i Wake Up Intensity cont START END PROGRAMMING BAR CODES 40 50 60 70 80 ...

Page 29: ...e Ka 3 30 IBM 4683 Port 9B 3 24 Keyboard Wedge La 3 30 IBM 4683 Port 17 3 24 Keyboard Wedge Ma 3 30 USB Keyboard Wedge Na 3 30 IBM USB 3 24 Keyboard Wedge Na 3 30 USB Keyboard 3 24 Keyboard Wedge Oa 3 30 Wand Emulation Keyboard Wedge Pa 3 30 Wand Emulation 3 26 Keyboard Wedge Qa 3 30 Keyboard Wedge 3 30 Keyboard Wedge Ra 3 30 Keyboard Wedge Aa a Consult Table for more information regarding keyboar...

Page 30: ... 120 185 325 Style IBM Enhanced PC M WYSE 60 85 99 GT 150 160 285 ANSI Keyboard 105 Keys 520 520 ES ANSI Keyboard 105 Keys WYSE 55 65 65 ES 120 185 325 ANSI Keyboard 105 Keys N WYSE 60 85 99 GT 150 160 285 ASCII Kbd 520 520 ES ASCII Kbd WYSE 55 65 65 ES 120 185 325 ASCII Keyboard O WYSE 60 85 99 GT 150 160 285 ANSI W285 Keyboard 105 Keys 520 520 ES ANSI W285 Keyboard 105 Keys WYSE 55 65 65 ES 120 ...

Page 31: ...Product Reference Guide 3 3 Interface Selection START END PROGRAMMING BAR CODES RS 232 Standard RS 232 Wincor Nixdorf IBM 4683 Port 5B IBM 4683 Port 9B IBM 4683 Port 17 IBM USB USB Keyboard Wand Emulation Keyboard Wedge A ...

Page 32: ...3 4 Magellan 1400i Interface Selection cont START END PROGRAMMING BAR CODES Keyboard Wedge B Keyboard Wedge C Keyboard Wedge D Keyboard Wedge E Keyboard Wedge F Keyboard Wedge G Keyboard Wedge H Keyboard Wedge I Keyboard Wedge J ...

Page 33: ...Reference Guide 3 5 Interface Selection cont START END PROGRAMMING BAR CODES Keyboard Wedge K Keyboard Wedge L Keyboard Wedge M Keyboard Wedge N Keyboard Wedge O Keyboard Wedge P Keyboard Wedge Q Keyboard Wedge R Keyboard Wedge S ...

Page 34: ...nterface Related Features 3 6 Magellan 1400i Interface Selection cont START END PROGRAMMING BAR CODES Keyboard Wedge T Keyboard Wedge U Keyboard Wedge V Keyboard Wedge W Keyboard Wedge X Keyboard Wedge Y ...

Page 35: ...set to ignore host commands the scanner will ignore all host commands except for the minimum set necessary to keep the interface active and transmit labels For normal operation of the interface select Obey Host Commands START END PROGRAMMING BAR CODES Obey Host Commands DEFAULT Ignore Host Commands ...

Page 36: ... is being transmitted to the host Selecting BUFFERS 1 means that the first bar code must be transmitted before a new one can be read A selection of BUFFERS 2 means that a new bar code can be read while data from the first bar code is transmitted When a DISABLE SCANNER command is received from the host the scanner will continue to transmit all data that is buffered START END PROGRAMMING BAR CODES H...

Page 37: ...Interface Features Product Reference Guide 3 9 RS 232 Interface Features START END PROGRAMMING BAR CODES 1200 Baud 2400 Baud 4800 Baud 9600 Baud DEFAULT 19200 Baud 38400 Baud 57600 Baud 115200 Baud ...

Page 38: ...ce Related Features 3 10 Magellan 1400i RS 232 Interface Features cont START END PROGRAMMING BAR CODES 7 Data Bits 8 Data Bits DEFAULT 1 Stop Bit DEFAULT 2 Stop Bits Parity None DEFAULT Parity Even Parity Odd ...

Page 39: ...nsmission of data to the host Enable CTS Scan Control The CTS line must be active for the scanner to read and trans mit data While the CTS line is inactive the scanner remains in a host disabled state following a successful label transmission the CTS signal must transition to inactive and then to active to enable scanning for the next label START END PROGRAMMING BAR CODES Disable Hardware Control ...

Page 40: ...ssion speed is too high the system may not be able to receive all characters You may need to adjust the delay to make the system work properly START END PROGRAMMING BAR CODES Inter Char Delay No Delay DEFAULT Interchar Delay 10 msec Interchar Delay 20 msec Interchar Delay 30 msec Interchar Delay 40 msec Interchar Delay 50 msec Interchar Delay 60 msec Interchar Delay 70 msec ...

Page 41: ...ay cont Software Flow Control Disables Enables software control using XON XOFF characters START END PROGRAMMING BAR CODES Interchar Delay 80 msec Interchar Delay 90 msec START END PROGRAMMING BAR CODES Disable Software Flow Control DEFAULT Enable Software Flow Control ...

Page 42: ...xample one of the devices in the chain is a terminal where someone is entering data while another person is simultaneously scanning a bar code requiring transmission to the host the scanner will wait for the RS 232 channel to be quiet for a specified period of time set via RS 232 Host Echo Quiet Interval The scanner can be set to observe this delay before sending its data in order to avoid RS 232 ...

Page 43: ...he scanner will break the host echo loop to transmit the bar code data that has just been scanned to the host START END PROGRAMMING BAR CODES Host Echo Quiet Interval 0msec Host Echo Quiet Interval 10msec DEFAULT Host Echo Quiet Interval 20msec Host Echo Quiet Interval 30msec Host Echo Quiet Interval 40msec Host Echo Quiet Interval 50msec Host Echo Quiet Interval 60msec Host Echo Quiet Interval 70...

Page 44: ...pecifies whether the RS 232 interface provides TTL levels on the output pins TxD and RTS START END PROGRAMMING BAR CODES Host Echo Quiet Interval 80msec Host Echo Quiet Interval 90msec Host Echo Quiet Interval 100msec START END PROGRAMMING BAR CODES Signal Voltage Normal RS 232 DEFAULT Signal Voltage TTL ...

Page 45: ...of RS 232 TXD and RXD signals Beep on ASCII BEL Enables disables ability of scanner to beep sound a good read tone on receiving an ASCII BEL 07 hex START END PROGRAMMING BAR CODES Disable RS 232 Invert DEFAULT Enable RS 232 Invert START END PROGRAMMING BAR CODES Enable Beep on ASCII BEL DEFAULT Disable Beep on ASCII BEL ...

Page 46: ... RS 232 Interface Features cont Beep on Not on File Select for the host to beep or not when a not on file host command condition is detected by the host START END PROGRAMMING BAR CODES Disable Beep on Not On File Enable Beep on Not On File DEFAULT ...

Page 47: ...s in error Selections for this option are Disable Enable for label transmission the scanner expects an ACK NAK response from the host when a label is sent Enable for host command acknowledge the scanner will respond with ACK NAK when the host sends a command Enable for label transmission and host command acknowledge START END PROGRAMMING BAR CODES Disable ACK NAK DEFAULT Enable ACK NAK for Transmi...

Page 48: ...ting your desired character Exit programming mode by again scanning the START END bar code above DEFAULT SETTING FOR THIS FEATURE 006 ACK Set ACK Character START END PROGRAMMING BAR CODES Sets the NAK character from the set of ASCII characters or any decimal value from 000 to 255 Pad entries of less than three digits with zeros as in 005 To configure this feature scan the START END bar code above ...

Page 49: ...em specifies the time the scanner will wait for an ACK character from the host following a label transmission 000 Infinite timeout 001 075 Timeout in 200 millisecond increments To configure this feature scan the START END bar code above to place the unit in Programming Mode then the Set ACK NAK Timeout Value followed by the two digits zero padded from the Alphanumeric table in Appendix C Alpha Num...

Page 50: ...Retry for the specified number of times 255 Retry forever To configure this feature scan the START END bar code above to place the unit in Programming Mode then the Set ACK NAK Retry Count followed by the three digits zero padded from the Alphanumeric table in Appendix C Alpha Numeric Pad repre senting your desired retry count Exit programming mode by again scanning the START END bar code above DE...

Page 51: ...host Errors include unrecognized host commands and com munication errors such as parity or framing errors Choices are 00 Ignore errors detected recommended setting 01 Process error as valid ACK character risk of lost label data 02 Process error as valid NAK character risk of duplicate label data START END PROGRAMMING BAR CODES Ignore Errors Detected DEFAULT Process error as valid ACK character Pro...

Page 52: ...entified as one of two different types of bar code scanners Depending on what other scanners you may already have connected to a IBM USB POS you may need to change this setting to enable all devices to communicate Options are Table Top Scanner Handheld Scanner START END PROGRAMMING BAR CODES Disable Transmission Error Indication Enable Transmission Error Indication DEFAULT START END PROGRAMMING BA...

Page 53: ...t a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host This applies to Code 128 Coda bar and Code 93 for IBM USB Code 128 Codabar and Code 93 for IBM Port 5B and Coda bar and Code 93 for IBM Port 9B START END PROGRAMMING BAR CODES Disable Convert to Code 39 DEFAULT Enable Convert to Code 39 ...

Page 54: ... Emulation Bar Code Format The following format settings are required for the wand emulation interface These settings have been pre configured at the factory for Wand Emulation scanners UPC A bar codes must include all 12 digits UPC E bar codes must contain 8 digits including a system digit 6 data digits and the check digit EAN 13 bar codes must have all 13 digits EAN 8 bar codes must include all ...

Page 55: ...ill be transmitted as a high voltage level 2 4 to 5 25V and space as low level 0 to 0 7V Wand Idle State This feature specifies the level of the wand output signal when idle TTL logic levels High voltage level 2 4 to 5 25V Low voltage level 0 to 0 7V START END PROGRAMMING BAR CODES Bar Space Low High Bar Space High Low DEFAULT START END PROGRAMMING BAR CODES Wand Idle State Low DEFAULT Wand Idle S...

Page 56: ...s the width of the minimum narrow bar 330 microseconds 660 microseconds Transmit Trailing Noise The transmission of noise pulses after the label may be enabled or disabled START END PROGRAMMING BAR CODES Signal Speed 330mS Signal Speed 660mS DEFAULT START END PROGRAMMING BAR CODES Disable Trailing Noise Enable Trailing Noise DEFAULT ...

Page 57: ...be enabled or disabled Symbology Conversion Wand Emulation can convert all bar codes to a single symbology Choices are No Conversion Convert to Code 39 Convert to Code 128 START END PROGRAMMING BAR CODES Disable Leading Noise Enable Leading Noise DEFAULT START END PROGRAMMING BAR CODES No Symbology Conversion DEFAULT Convert to C39 Convert to C128 ...

Page 58: ...le process that doesn t require any changes of software or hard ware Keyboard Layout The Keyboard Layout option supports many countries For details about Keyboard Layout please refer to your operating system manual NOTE All of the options in this section apply to the Key board Wedge however only some apply to USB Key board START END PROGRAMMING BAR CODES USA DEFAULT Belgium Britain Denmark France ...

Page 59: ...Interface Features Product Reference Guide 3 31 Keyboard Wedge cont START END PROGRAMMING BAR CODES Italy Norway Portugal Spain Sweden Switzerland Japan 106 Key Hungary Czech ...

Page 60: ... Keyboard Wedge cont Caps Lock State Specifies the format in which the scanner sends character data START END PROGRAMMING BAR CODES Slovakia Romania Croatia Poland START END PROGRAMMING BAR CODES Disable Caps Lock DEFAULT Caps Lock ON Shift Lock ON ...

Page 61: ...t is recommended that you enable this function if you are working without a keyboard installation It simulates keyboard timing and passes the keyboard status to the PC during power on NOTE This feature does not apply to the USB Keyboard interface START END PROGRAMMING BAR CODES Disable Power on Simulation DEFAULT Enable Power on Simulation 0 2 8 9 0 1 ...

Page 62: ...control characters to host Send characters between 00H and 1FH according to a special function key mapping table This is used to send keys that are not in the normal ASCII set a unique set is pro vided for each available scancode set Reference Appendix E Keyboard Function Key Map pings START END PROGRAMMING BAR CODES Disable Control Characters DEFAULT Enable Transmission of Control Characters Enab...

Page 63: ... START END PROGRAMMING BAR CODES Selectable from 000 no interval to 255 in 10 msec increments To configure this feature scan the START END bar code above to place the unit in Programming Mode then the Set Wedge Quiet Interval bar code followed by the three digits zero padded from the Alphanumeric table in Appendix C Alpha Numeric Pad representing your desired length Exit programming mode by again ...

Page 64: ...receive all characters You may need to adjust the delay to make the system work properly Selectable from 000 to 255 in 10msec increments To configure this feature scan the START END bar code above to place the unit in Pro gramming Mode then the Set Intercharacter Delay followed by the three digits zero padded from the Alphanumeric table in Appendix C Alpha Numeric Pad representing your desired len...

Page 65: ...tring is not a mandatory requirement Data editing is sophisticated feature allowing highly customizable output for advanced users Factory default settings for data editing is typically set to NONE A prefix or suffix may be applied reference the Symbologies chapter for these settings across all symbologies set via the Global features in this chapter You can add any character from the ASCII Chart fr...

Page 66: ...lar sign as a prefix 2 Scan the START bar code 3 Scan the SET PREFIX bar code 4 Reference the ASCII Chart on the inside back cover of this manual to find the hex value assigned to the desired character The corresponding hex number for the character is 24 To enter this selection code scan the 2 and 4 bar codes from Appendix C Alpha Numeric Pad 5 Scan the END bar code to exit Programming Mode 6 The ...

Page 67: ...ace the unit in Programming Mode then the Set Prefix or Set Suffix followed by the digits from the Alphanumeric table in Appendix C Alpha Numeric Pad representing your desired character s Reference the section Example Setting a Prefix for more information Exit programming mode by scanning the START END barcode again scan START END twice if less than 20 characters have been selected DEFAULT SETTING...

Page 68: ...llows A close brace character ASCII followed by A code character see the table below followed by A modifier character the modifier character is symbol dependent Figure 4 3 AIM ID SYMBOLOGY CHAR SYMBOLOGY CHAR UPC EAN E Code 128 EAN 128 C Code 39 A MSI Plessey M Codabar F RSS RSS 14 RSS Expanded e Interleaved 2 of 5 I Standard 2 of 5 S Code 93 G ISBN Xa a ISBN X with a 0 modifier character Prefix S...

Page 69: ...er BEFORE or AFTER by scanning the appropriate bar code 3 Scan a bar code to select the symbology for which you wish to configure a custom Label ID 4 Determine the desired character s you may choose either one or two which will repre sent the Label ID for the selected symbology Next turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with y...

Page 70: ... UPC A Label ID Character s DEFAULT SETTING FOR THIS FEATURE A 41 hex DEFAULT SETTING FOR THIS FEATURE A 41 hex Set UPC A w P2 Addon Label ID Character s Set UPC A w P5 Addon Label ID Character s DEFAULT SETTING FOR THIS FEATURE A 41 hex DEFAULT SETTING FOR THIS FEATURE A 41 hex Set UPC A w C128 Addon Label ID Character s Set UPC E Label ID Character s DEFAULT SETTING FOR THIS FEATURE E 45 hex ...

Page 71: ...ATURE E 45 hex Set UPC E w C128 Addon Label ID Character s Set EAN 8 Label ID Character s DEFAULT SETTING FOR THIS FEATURE FF 4646 hex DEFAULT SETTING FOR THIS FEATURE FF 4646 hex Set EAN 8 w P2 Addon Label ID Character s Set EAN 8 w P5 Addon Label ID Character s DEFAULT SETTING FOR THIS FEATURE FF 4646 hex DEFAULT SETTING FOR THIS FEATURE FF 4646 hex Set EAN 8 w C128 Addon Label ID Character s Se...

Page 72: ...IS FEATURE F 46 hex Set EAN 13 w C128 Addon Label ID Character s Set ISBN Label ID Character s DEFAULT SETTING FOR THIS FEATURE I 49 hex DEFAULT SETTING FOR THIS FEATURE IA 4941 hex Set IATA Label ID Character s Set GTIN Label ID Character s DEFAULT SETTING FOR THIS FEATURE G 47 hex DEFAULT SETTING FOR THIS FEATURE G2 4732 hex Set GTIN w P2 addon Label ID Character s Set GTIN w P5 addon Label ID C...

Page 73: ...T SETTING FOR THIS FEATURE RX 5258 hex Set RSS Expanded Label ID Character s Set RSS Limited Label ID Character s DEFAULT SETTING FOR THIS FEATURE RL 524C hex DEFAULT SETTING FOR THIS FEATURE 2A hex Set Code 39 Label ID Character s Set Pharmacode 39 Label ID Character s DEFAULT SETTING FOR THIS FEATURE A 41 hex DEFAULT SETTING FOR THIS FEATURE 23 hex Set Code 128 Label ID Character s Set I 2 of 5 ...

Page 74: ... FEATURE 26 hex DEFAULT SETTING FOR THIS FEATURE 40 hex Set Code 11 Label ID Character s Set MSI Plessey Label ID Character s DEFAULT SETTING FOR THIS FEATURE 40 hex DEFAULT SETTING FOR THIS FEATURE s 73 hex Set Std 2 of 5 Label ID Character s Set PDF417 Label ID Character s DEFAULT SETTING FOR THIS FEATURE P 5000 hex DEFAULT SETTING FOR THIS FEATURE mP 6D50 hex Set Micro PDF417 Label ID Character...

Page 75: ...code data to either all lower case a through z or all upper case A through Z characters NOTE Case conversion affects ONLY scanned bar code data and does not affect Label ID Prefix Suffix or other appended data START END PROGRAMMING BARCODES Disable DEFAULT Convert to Upper Case Convert to Lower Case ...

Page 76: ...n BG25TB82 The A characters were converted to the B character and the 1 characters were converted to the numeral 2 character Nothing is done with the last two character pairs since they are all FF To set Character Conversion 1 Scan the START END bar code 2 Scan the Character Conversion bar code 3 Determine the desired string Up to sixteen positions can be determined as in the above example Next tu...

Page 77: ...hout this section Reference Appendix D Default Settings for default exceptions for your interface UPC A Disable Enable UPC A When disabled the scanner will not read UPC A bar codes UPC A Pharmacode 39 UPC E Transmit Function Characters EAN 13 Interleaved 2 of 5 EAN 8 Codabar RSS 14 Code 93 RSS Expanded MSI Plessey RSS Limited Standard 2 of 5 Code 39 2D Symbologies PDF417 Micro PDF417 START END PRO...

Page 78: ...C A bar code data Expand UPC A to EAN 13 Expands UPC A data to the EAN 13 data format Selecting this feature also changes the sym bology ID to match those required for EAN 13 START END PROGRAMMING BAR CODES Don t Send Check Digit Send Check Digit DEFAULT START END PROGRAMMING BAR CODES Don t Expand to EAN 13 DEFAULT Expand to EAN 13 ...

Page 79: ...nimum Reads This feature specifies the minimum number of consecutive times a UPC A label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Disable Number System Transmission Enable Number System Transmission DEFAULT START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 80: ...re Minimum Reads This feature specifies the minimum number of consecutive times an in store printed label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 81: ...C E When disabled the scanner will not read UPC E bar codes Check Digit Transmission Enable this option to transmit the check digit along with UPC E bar code data START END PROGRAMMING BAR CODES Disable UPC E Enable UPC E DEFAULT START END PROGRAMMING BAR CODES Don t Send Check Digit Send Check Digit DEFAULT ...

Page 82: ...ot with scanned bar code data Expand UPC E to UPC A Enables disables expansion of UPC E labels to UPC A Selecting this feature also changes the symbology ID to match those required for UPC A START END PROGRAMMING BAR CODES Exclude Number System Digit DEFAULT Include Number System Digit START END PROGRAMMING BAR CODES Don t Expand UPC E to UPC A DEFAULT Expand UPC E to UPC A ...

Page 83: ...ID to match those required for EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times a UPC E label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Don t Expand UPC E to EAN 13 DEFAULT Expand UPC E to EAN 13 START END PROGRAMMING BAR CODES Minimum 1 Read Minimum 2 Reads DEFAULT Minimum 3 Reads Minimum 4 Reads ...

Page 84: ...wing options apply to the GTIN label data format Expand UPC EAN to GTIN When this feature is enabled the scanner will translate UPC EAN labels to the 14 digit GTIN format START END PROGRAMMING BAR CODES Don t Expand to GTIN DEFAULT Expand to GTIN ...

Page 85: ... 13 When disabled the scanner will not read EAN 13 bar codes Check Digit Transmission Enable this option to transmit the check digit along with EAN 13 bar code data START END PROGRAMMING BAR CODES Disable EAN 13 Enable EAN 13 DEFAULT START END PROGRAMMING BAR CODES Don t Send Check Digit Send Check Digit DEFAULT ...

Page 86: ...hat contain ISBN International Standard Book Number and appends an ISBN check character to the end of the label These codes are used for books and magazines Labels with ISBN codes start with 978 Example Bar code data 9789572222720 Output 9572222724 START END PROGRAMMING BAR CODES Don t Transmit EAN 13 Flag 1 Char Transmit EAN 13 Flag 1 Char DEFAULT START END PROGRAMMING BAR CODES Disable ISBN DEFA...

Page 87: ...ed Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 88: ... 8 When disabled the scanner will not read EAN 8 bar codes Check Digit Transmission Enable this option to transmit the check Digit along with EAN 8 bar code data START END PROGRAMMING BAR CODES Disable EAN 8 Enable EAN 8 DEFAULT START END PROGRAMMING BAR CODES Don t Send Check Digit Send Check Digit DEFAULT ...

Page 89: ...gy ID to match those required for EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Don t Expand to EAN 13 DEFAULT Expand to EAN 13 START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 90: ...EAN Two Label Combined Enables disables the transmitting of an EAN two label pair as one label START END PROGRAMMING BAR CODES Disable EAN Two Label Enable EAN Two Label START END PROGRAMMING BAR CODES Disable EAN Two Label Combined Enable EAN Two Label Combined NOTE Contact Customer Support for advanced programming of Two Label Pairs ...

Page 91: ...ed options are None This option directs the scanner to ignore add on portion of a UPC EAN bar code but still read the main portion of the bar code 2 Digits The scanner will optionally read 2 digit add ons with the UPC EAN label 5 Digits The scanner will optionally read 5 digit add ons with the UPC EAN label Code 128 Add on The scanner will optionally read Code 128 add ons with the UPC EAN label NO...

Page 92: ...START END PROGRAMMING BAR CODES Disable Optional 2 Digit Add ons DEFAULT Enable Optional 2 Digit Add ons Disable Optional 5 Digit Add ons DEFAULT Enable Optional 5 Digit Add ons Disable Optional Code 128 Add ons DEFAULT Enable Optional Code 128 Add ons ...

Page 93: ...bled the scanner will not read RSS 14 bar codes RSS 14 UCC EAN 128 Emulation When enabled RSS 14 bar codes will be translated to the UCC EAN 128 label data format START END PROGRAMMING BAR CODES Disable RSS 14 DEFAULT Enable RSS 14 START END PROGRAMMING BAR CODES Disable RSS 14 UCC EAN 128 Emulation DEFAULT Enable RSS 14 UCC EAN 128 Emulation ...

Page 94: ... Minimum Reads This feature specifies the minimum number of consecutive times an RSS 14 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 95: ... Component This setting enables disables RSS 14 Micro PDF417 composite labels NOTE Both RSS 14 and Micro PDF417 must be enabled to read these composite labels START END PROGRAMMING BAR CODES Disable RSS 14 2D Component DEFAULT Enable always on RSS 14 2D Component ...

Page 96: ...r will not read RSS Expanded bar codes RSS Expanded UCC EAN 128 Emulation When enabled RSS Expanded bar codes will be translated to the UCC EAN 128 label data for mat START END PROGRAMMING BAR CODES Disable RSS Expanded DEFAULT Enable RSS Expanded START END PROGRAMMING BAR CODES Disable RSS Expanded UCC EAN 128 Emulation DEFAULT Enable RSS Expanded UCC EAN 128 Emulation ...

Page 97: ...de 4 Set Length 1 to the first fixed length by following the RSS Expanded Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed length by following the RSS Expanded Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START END bar code 2 Scan the Variable Length Decoding bar code ...

Page 98: ...bar code 3 Turn to Appendix C Alpha Numeric Pad and scan the three digits zero padded represent ing the length in decimal notation 4 Scan the START END bar code NOTE For RSS Expanded bar codes only the data characters are included in the length calcula tions START END PROGRAMMING BAR CODES DEFAULT SETTING FOR THIS FEATURE 008 Set Length 1 Set Length 2 DEFAULT SETTING FOR THIS FEATURE 014 ...

Page 99: ...inued Minimum Reads This feature specifies the minimum number of consecutive times an RSS Expanded label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 100: ... Limited symbology Disable Enable RSS Limited When this feature is disabled the scanner will not read RSS Limited bar codes NOTE Both RSS Expanded and Micro PDF417 must be enabled to read these composite labels START END PROGRAMMING BAR CODES Disable RSS Expanded 2D Component DEFAULT Enable always on RSS Expanded 2D Component START END PROGRAMMING BAR CODES Disable RSS Limited DEFAULT Enable RSS L...

Page 101: ...or mat Minimum Reads This feature specifies the minimum number of consecutive times an RSS Limited label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Disable RSS Limited UCC EAN 128 Emulation DEFAULT Enable RSS Limited UCC EAN 128 Emulation START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 102: ...ent This setting enables disables RSS Limited Micro PDF417 composite labels NOTE Both RSS Limited and Micro PDF417 must be enabled to read these composite labels START END PROGRAMMING BAR CODES Disable RSS Limited 2D Component DEFAULT Enable always on RSS Limited 2D Component ...

Page 103: ...t read Code 39 bar codes Check Character Calculation When enabled the scanner will calculate the check character of the labels Turn this option on only when a checksum is present in the Code 39 labels START END PROGRAMMING BAR CODES Disable Code 39 Enable Code 39 DEFAULT START END PROGRAMMING BAR CODES Disable Check Char Calculation DEFAULT Enable Check Char Calculation ...

Page 104: ... with scanned bar code data Start Stop Characters Enables disables transmission of Code39 start and stop characters START END PROGRAMMING BAR CODES Disable Check Char Transmission Enable Check Char Transmission DEFAULT START END PROGRAMMING BAR CODES Don t Transmit Start Stop Characters DEFAULT Transmit Start Stop Characters ...

Page 105: ...Guide 5 29 Code 39 continued Code 39 Full ASCII Enables disables the translation of Code 39 characters to Code 39 full ASCII characters START END PROGRAMMING BAR CODES Disable Code 39 Full ASCII DEFAULT Enable Code 39 Full ASCII ...

Page 106: ...ode 4 Set Length 1 to the first fixed length by following the Code 39 Length 1 Length 2 Program ming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed length by following the Code 39 Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START END bar code 2 Scan the Variable Length Decoding bar code 3 Scan t...

Page 107: ...RT END bar code Quiet Zones This feature enables disables the requirement that quiet zones must be present for Code 39 bar codes NOTE For Code 39 bar codes all check data and full ASCII shift characters even if full ASCII is enabled are included in the length calculations Start Stop charac ters are not included START END PROGRAMMING BAR CODES DEFAULT SETTING FOR THIS FEATURE 003 Set Length 1 Set L...

Page 108: ...by the scanner s software and the data will be decoded if all bar code proofing requirements are met Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Disable Code 39 Stitching DEFAULT Enable Code 39 Stitching START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum...

Page 109: ... feature is disabled the scanner will not read Pharmacode 39 bar codes Start Stop Characters Enables or disables transmission of Pharmacode 39 start stop characters START END PROGRAMMING BAR CODES Disable Pharmacode 39 DEFAULT Enable Pharmacode 39 START END PROGRAMMING BAR CODES Don t Transmit Start Stop Characters DEFAULT Transmit Start Stop Characters ...

Page 110: ...i Pharmacode 39 continued Check Character Transmit Enable this option to transmit the check character with scanned bar code data START END PROGRAMMING BAR CODES Disable Check Char Transmission Enable Check Char Transmission DEFAULT ...

Page 111: ...gies Code 128 When this feature is disabled the scanner will not read Code 128 bar codes UCC EAN 128 Enables disables ability of scanner to translate UCC EAN 128 labels to the EAN 128 data format START STATE BARCODE Disable Code 128 Enable Code 128 Transmit EAN128 labels in Code128 data format Transmit EAN128 labels in EAN128 data format END ...

Page 112: ...tion Characters Enables disables transmission of Code128 function characters 1 2 3 and 4 Function codes are transmitted as follows FNC1 80 hex FNC2 81 hex FNC3 82 hex FNC4 83 hex START END PROGRAMMING BAR CODES Don t Transmit Function Characters DEFAULT Transmit Function Characters ...

Page 113: ...Scan the END bar code 4 Set Length 1 to the first fixed length by following the Code 128 Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed length by following the Code 128 Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START bar code 2 Scan the Variable Length Decoding b...

Page 114: ...e digits zero padded represent ing the length in decimal notation 4 Scan the END bar code Code 128 Conversion to Code 39 Enables disables expansion of Code 128 labels to Code 39 NOTE For Code 128 bar codes only the data charac ters are included in the length calculations START END PROGRAMMING BAR CODES DEFAULT SETTING FOR THIS FEATURE 001 Set Length 1 Set Length 2 DEFAULT SETTING FOR THIS FEATURE ...

Page 115: ...s will be assembled by the scan ner s software and the data will be decoded if all bar code proofing requirements are met Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Disable Code 128 Stitching DEFAULT Enable Code 128 Stitching START END PROGRAMMING BAR CODES Minimu...

Page 116: ...is feature is disabled the scanner will not read Interleaved 2 of 5 bar codes Check Digit Calculation When enabled the scanner will calculate the check digit of the labels START END PROGRAMMING BAR CODES Disable Interleaved 2 of 5 DEFAULT Enable Interleaved 2 of 5 START END PROGRAMMING BAR CODES Disable Check Digit Calculation DEFAULT Enable Check Digit Calculation ...

Page 117: ... Guide 5 41 Interleaved 2 of 5 continued Check Digit Transmit Enable this option to transmit the check digit with scanned bar code data START END PROGRAMMING BAR CODES Disable Check Digit Calculation DEFAULT Enable Check Digit Calculation ...

Page 118: ...h 1 to the first fixed length by following the Interleaved 2 of 5 Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed length by following the Interleaved 2 of 5 Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START bar code 2 Scan the Variable Length Decoding bar code 3 Scan...

Page 119: ...rn to Appendix C Alpha Numeric Pad and scan the three digits zero padded represent ing the length in decimal notation 4 Scan the END bar code NOTE For Interleaved 2 of 5 bar codes lengths must be an even number Additionally all check and data characters are included in the length calcu lations START END PROGRAMMING BAR CODES DEFAULT SETTING FOR THIS FEATURE 006 Set Length 1 Set Length 2 DEFAULT SE...

Page 120: ... of 5 bar code are presented to the scanner with this feature enabled the bar code parts will be assembled by the scanner s software and the data will be decoded if all bar code proofing requirements are met NOTE Only functions when Fixed Length Decoding is enabled START END PROGRAMMING BAR CODES Disable Interleaved 2 of 5 Stitching DEFAULT Enable Interleaved 2 of 5 Stitching ...

Page 121: ...ontinued Minimum Reads This feature specifies the minimum number of consecutive times an Interleaved 2 of 5 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 122: ...re is disabled the scanner will not read Codabar bar codes Check Character Verification When enabled the scanner will verify the check character of the labels START END PROGRAMMING BAR CODES Disable Codabar DEFAULT Enable Codabar START END PROGRAMMING BAR CODES Disable Check Char Verification DEFAULT Enable Check Char Verification ...

Page 123: ...de 5 47 Codabar continued Check Character Transmit Enable this option to transmit the check character with scanned bar code data START END PROGRAMMING BAR CODES Disable Check Char Transmission Enable Check Char Transmission DEFAULT ...

Page 124: ...code 4 Set Length 1 to the first fixed length by following the Codabar Length 1 Length 2 Program ming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed length by following the Codabar Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START bar code 2 Scan the Variable Length Decoding bar code 3 Scan the ...

Page 125: ...ngth in decimal notation 4 Scan the END bar code Quiet Zones This feature enable disables the requirement that quiet zones must be present for Codabar bar codes NOTE For Codabar bar codes all start stop check and data characters are included in the length calculations START END PROGRAMMING BAR CODES DEFAULT SETTING FOR THIS FEATURE 003 Set Length 1 Set Length 2 DEFAULT SETTING FOR THIS FEATURE 050...

Page 126: ... Start Stop Character Transmission The transmission of start and end characters of Codabar is selected below START END PROGRAMMING BAR CODES Start Stop Type ABCD TN E Start Stop Type ABCD ABCD Start Stop Type abcd tn e Start Stop Type abcd abcd DEFAULT START END PROGRAMMING BAR CODES Disable Start Stop Char Transmission Enable Start Stop Char Transmission DEFAULT ...

Page 127: ...bar label are presented to the scanner with this feature enabled the bar code parts will be assembled by the scanner s soft ware and the data will be decoded if all bar code proofing requirements are met START END PROGRAMMING BAR CODES Disable Start Stop Char Match DEFAULT Enable Start Stop Char Match NOTE Only functions when Fixed Length Decoding is enabled START END PROGRAMMING BAR CODES Disable...

Page 128: ...d Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 129: ...5 53 Code 93 The following options apply to the Code 93 symbology Disable Enable Code 93 When this feature is disabled the scanner will not read Code 93 bar codes START END PROGRAMMING BAR CODES Disable Code 93 DEFAULT Enable Code 93 ...

Page 130: ...ode 4 Set Length 1 to the first fixed length by following the Code 93 Length 1 Length 2 Program ming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed length by following the Code 93 Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START END bar code 2 Scan the Variable Length Decoding bar code 3 Scan t...

Page 131: ... bar code 3 Turn to Appendix C Alpha Numeric Pad and scan the three digits zero padded represent ing the length in decimal notation 4 Scan the END bar code NOTE For Code 93 bar codes only the data characters are included in the length calculations START END PROGRAMMING BAR CODES DEFAULT SETTING FOR THIS FEATURE 001 Set Length 1 Set Length 2 DEFAULT SETTING FOR THIS FEATURE 050 ...

Page 132: ...by the scanner s software and the data will be decoded if all bar code proofing requirements are met Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Disable Code 93 Stitching DEFAULT Enable Code 93 Stitching START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum...

Page 133: ...is disabled the scanner will not read MSI Plessey bar codes Check Digit Verification This feature specifies whether one or two check digits are to be calculated and verified START END PROGRAMMING BAR CODES Disable MSI Plessey DEFAULT Enable MSI Plessey START END PROGRAMMING BAR CODES Disable Check Digit Verification DEFAULT Enable Check Digit Verification ...

Page 134: ...heck digits depending upon the setting for check digit verification Number of Check Characters Specifies number of MSI Plessey check characters to be calculated and verified START END PROGRAMMING BAR CODES Disable Check Digit Transmission Enable Check Digit Transmission DEFAULT START END PROGRAMMING BAR CODES 1 Check Character DEFAULT 2 Check Characters ...

Page 135: ...ode 4 Set Length 1 to the first fixed length by following the MSI Plessey Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed length by following the MSI Plessey Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START END bar code 2 Scan the Variable Length Decoding bar code ...

Page 136: ...r code 3 Turn to Appendix C Alpha Numeric Pad and scan the three digits zero padded represent ing the length in decimal notation 4 Scan the END bar code NOTE For MSI Plessey bar codes all check and data characters are included in the length calculations START END PROGRAMMING BAR CODES DEFAULT SETTING FOR THIS FEATURE 004 Set Length 1 Set Length 2 DEFAULT SETTING FOR THIS FEATURE 016 ...

Page 137: ...lessey label are presented to the scanner with this feature enabled the bar code parts will be assembled by the scanner s software and the data will be decoded if all bar code proofing requirements are met NOTE Only functions when Fixed Length Decoding is enabled START END PROGRAMMING BAR CODES Disable MSI Plessey Stitching DEFAULT Enable MSI Plessey Stitching ...

Page 138: ... Minimum Reads This feature specifies the minimum number of consecutive times an MSI Plessey label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 139: ...When this feature is disabled the scanner will not read Standard 2 of 5 bar codes Check Digit Verification When enabled the scanner will verify the check digit of the labels START END PROGRAMMING BAR CODES Disable Std 2 of 5 DEFAULT Enable Std 2 of 5 START END PROGRAMMING BAR CODES Disable Check Digit Verification DEFAULT Enable Check Digit Verification ...

Page 140: ...1400i Standard 2 of 5 continued Check Digit Transmit When this option is enabled the scanner will transmit the check digit START END PROGRAMMING BAR CODES Disable Check Digit Transmission Enable Check Digit Transmission DEFAULT ...

Page 141: ...4 Set Length 1 to the first fixed length by following the Standard 2 of 5 Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed length by following the Standard 2 of 5 Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START END bar code 2 Scan the Variable Length Decoding bar co...

Page 142: ...bar code 3 Turn to Appendix C Alpha Numeric Pad and scan the three digits zero padded represent ing the length in decimal notation 4 Scan the END bar code NOTE For Standard 2 of 5 bar codes all check and data characters are included in the length calcu lations START END PROGRAMMING BAR CODES DEFAULT SETTING FOR THIS FEATURE 008 Set Length 1 Set Length 2 DEFAULT SETTING FOR THIS FEATURE 050 ...

Page 143: ... Standard 2 of 5 label are presented to the scanner with this feature enabled the bar code parts will be assembled by the scanner s software and the data will be decoded if all bar code proofing requirements are met NOTE Only functions when Fixed Length Decoding is enabled START END PROGRAMMING BAR CODES Disable Std 2 of 5 Stitching DEFAULT Enable Std 2 of 5 Stitching ...

Page 144: ...d Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 145: ...er will not read PDF417 bar codes PDF417 Minimum Reads This feature specifies the minimum number of consecutive times a PDF417 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Disable PDF417 DEFAULT Enable PDF417 START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 146: ...rst fixed length by following the PDF417 Length 1 Length 2 Program ming Instructions below 4 Set Length 2 to the second fixed length or to 000 if there is only one fixed length by following the PDF417 Length 1 Length 2 Programming Instructions below 5 Scan the START END bar code Configuring Variable Length Decoding 1 Scan the START END bar code 2 Scan the Variable Length Decoding bar code 3 Set Le...

Page 147: ... Pad and scan the three digits zero padded represent ing the length in decimal notation 4 Scan the END bar code NOTE Length 2 is the maximum label length if in vari able length mode or the second fixed length if in fixed length mode Length includes the bar code s check and data characters START END PROGRAMMING BAR CODES DEFAULT SETTING FOR THIS FEATURE 001 Set Length 1 Set Length 2 DEFAULT SETTING...

Page 148: ... The following options apply to the Micro PDF417 symbology Disable Enable Micro PDF417 When this feature is disabled the scanner will not read Micro PDF417 bar codes START END PROGRAMMING BAR CODES Disable Micro PDF417 DEFAULT Enable Micro PDF417 ...

Page 149: ...DF 128 Emulation is disabled and the scanner is performing EAN128 or Code 128 emulation the scanned label type is recognized as MicroPDF If Micro PDF 128 Emulation is enabled and AIM ID is enabled and the scanner is perform ing EAN128 or Code 128 emulation the Code 128 EAN 128 AIM I D type is used C0 C1 or C2 If Micro PDF 128 Emulation is enabled and the scanner is performing EAN128 or Code 128 em...

Page 150: ... PDF417 Minimum Reads This feature specifies the minimum number of consecutive times a Micro PDF417 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1 Read DEFAULT Minimum 2 Reads Minimum 3 Reads Minimum 4 Reads ...

Page 151: ... fixed length by following the Micro PDF417 Length 1 Length 2 Pro gramming Instructions below 4 Set Length 2 to the second fixed length or to 000 if there is only one fixed length by following the Micro PDF417 Length 1 Length 2 Programming Instructions below 5 Scan the START END bar code Configuring Variable Length Decoding 1 Scan the START END bar code 2 Scan the Variable Length Decoding bar code...

Page 152: ...eric Pad and scan the three digits zero padded represent ing the length in decimal notation 4 Scan the END bar code NOTE Length 2 is the maximum label length if in vari able length mode or the second fixed length if in fixed length mode Length includes the bar code s check and data characters START END PROGRAMMING BAR CODES DEFAULT SETTING FOR THIS FEATURE 001 Set Length 1 Set Length 2 DEFAULT SET...

Page 153: ...r Dimensions Parameter Specification Scan Volume 80 cubic inches Scan Pattern 100 lines Scan Rate 1170 Digital Scan Lines second Minimum Resolution 5 mil Depth of Field 100 UPC Labels 0 8 Minimum Print Contrast Ratio 25 Skew Yaw 75q Pitch 65q Roll Between 0 and 360q 66mm 82mm 97mm 154mm Scanner 181mm w Stand ...

Page 154: ...Two Models 5V unit 5 0V 5 12V unit 8 14V 5 Input Current Operating idle Operating label read Surge Current 30 ms 350mA 450 mA 650mA Parameter Specification Mechanical Shock Multi 1 2m drops Contaminants Water and Dust IP52 Temperature Ranges Operating 32q F to 104q F 0q C to 40q C Storage 40q F to 158q F 40q C to 70qC Ambient Light Indoor 6000 lux Ambient Light Outdoor 86 100 lux Humidity 5 to 95 ...

Page 155: ...able Pinouts Standard Cable Pinouts Primary Interface Cables RS 232 IBM Port 5B 9B 17 1 2 CTS 3 4 RTS 5 RXD 6 TXD 7 8 VCC IN 9 GND 10 1 2 3 4 DATA 5 6 DATA 7 8 VCC_IN 9 GND 10 Pin 1 10 Position RJ Scanner End Pin 1 10 Position RJ Scanner End ...

Page 156: ...4 D 5 6 D 7 8 VIN 9 GND 10 1 2 3 4 D 5 6 D 7 8 VBUS_VIN 9 GND 10 1 2 3 WAND 4 5 6 7 8 VCC_IN 9 GND 10 1 2 KB_DATA 3 AT_CLK 4 KB_CLK 5 6 AT_DATA 7 8 VCC_IN 9 GND 10 Pin 1 10 Position RJ Scanner End Pin 1 10 Position RJ Scanner End Pin 1 10 Position RJ Scanner End Pin 1 10 Position RJ Scanner End ...

Page 157: ...Product Reference Guide C 1 Chapter C Alpha Numeric Pad A B C D E F ...

Page 158: ...C 2 Magellan 1400i Alpha Numeric Pad 1 2 3 0 9 8 7 6 5 4 ...

Page 159: ... Sleep Mode 10 minutes 2 5 Power On Alert Enable 2 7 Good Read When to Indicate After Decode 2 8 Good Read Beep Control Enable 2 9 Good Read Beep Fre quency Medium 2 9 Good Read Beep Length 60 msec 2 10 Good Read Beep Volume High 2 11 Target Mode Active Time Medium Duration 2 13 Target Mode Linger Time Medium Duration 2 14 Wake Up Intensity 10 2 15 Interface Selection RS 232 Std Interface as requi...

Page 160: ... Disable 3 13 Host Echo Disable 3 14 Host Echo Quiet Interval 10 msec 3 15 Signal Voltage Normal TTL Normal RS 232 3 16 RS 232 Invert Disable 3 17 Beep on ASCII BEL Enable 3 17 Beep on Not on File Enable 3 18 ACK NAK Options Disable 3 19 ACK Character ACK 3 20 NAK Character 3 20 Retry on ACK NAK Timeout Enable 3 21 ACK NAK Timeout Value 200 msec 3 21 ACK NAK Retry Count 3 3 22 ACK NAK Error Handli...

Page 161: ...nd Emulation Symbology Conversion Wand Emulation No Conversion 3 29 Keyboard Wedge USB Keyboard Keyboard Layout KBW USB KB USA 3 30 Keyboard Wedge USB Keyboard Caps Lock State KBW USB KB Disable 3 32 Keyboard Wedge USB Keyboard Power On Simulation KBW USB KB Disable 3 33 Keyboard Wedge USB Keyboard Control Characters KBW USB KB Disable 3 34 Keyboard Wedge USB Keyboard Wedge Quiet Interval KBW USB ...

Page 162: ...UPC E w P5 Addon Label ID E 4 7 UPC E w C128 Addon Label ID E 4 7 EAN 8 Label ID FF Wincor Nixdorf B 4 7 EAN 8 w P2 Addon Label ID FF 4 7 EAN 8 w P5 Addon Label ID FF 4 7 EAN 8 w C128 Addon Label ID FF 4 7 EAN 13 Label ID F Wincor Nixdorf F 4 7 EAN 13 w P2 Addon Label ID F 4 8 EAN 13 w P5 Addon Label ID F 4 8 EAN 13 w C128 Addon Label ID F 4 8 ISBN Label ID I Wincor Nixdorf A 4 8 GTIN Label ID G 4...

Page 163: ...9 Codabar Label ID Wincor Nixdorf N 4 10 Code 93 Label ID Wincor Nixdorf L 4 10 MSI Plessey Label ID Wincor Nixdorf O 4 10 Std 2 of 5 Label ID i Wincor Nixdorf H 4 10 PDF 417 Label ID P Wincor Nixdorf Q 4 10 Case Conversion Disable 4 11 Character Conversion No Conversion 4 12 Disable Enable UPC A Enable 5 1 UPC A Check Digit Transmission Send Check Digit 5 2 Expand UPC A to EAN 13 Don t Expand to ...

Page 164: ...N to GTIN Don t Expand 5 8 Disable Enable EAN 13 Enable 5 9 EAN 13 Check Digit Transmission Send Check Digit 5 9 EAN 13 Flag 1 Character Transmit 5 10 ISBN Disable 5 10 EAN 13 Minimum Reads 1 5 11 Disable Enable EAN 8 Enable 5 12 EAN 8 Check Digit Transmission Send Check Digit 5 12 Expand EAN 8 to EAN 13 Don t Expand 5 13 EAN 8 Minimum Reads 1 5 13 Enable EAN Two Label Disable 5 14 Enable EAN Two ...

Page 165: ... Variable Length 5 21 RSS Expanded Length 1 1 5 22 RSS Expanded Length 2 74 5 22 RSS Expanded Minimum Reads 1 5 23 Disable Enable Code 39 Enable 5 27 Code 39 Check Char acter Calculation Disable 5 27 Code 39 Check Char acter Transmit Enable 5 28 Code 39 Start Stop Characters Don t Transmit 5 28 Code 39 Full ASCII Disable 5 29 Code 39 Length Control Variable Length 5 30 Code 39 Length 1 3 5 31 Code...

Page 166: ...128 Length Control Variable Length 5 37 Code 128 Length 1 1 5 38 Code 128 Length 2 80 5 38 Code 128 Conversion to Code 39 Disable 5 38 Code 128 Stitching Disable 5 39 Code 128 Minimum Reads 1 5 39 Disable Enable Inter leaved 2 of 5 Disable 5 40 I 2 of 5 Check Digit Calculation Disable 5 40 I 2 of 5 Check Digit Transmit Enable 5 47 I 2 of 5 Length Control Variable Length 5 42 I 2 of 5 Length 1 6 5 ...

Page 167: ...pe abcd abcd 5 50 Codabar Start Stop Character Transmis sion Enable 5 50 Codabar Start Stop Character Match Disable 5 51 Codabar Stitching Disable 5 51 Codabar Minimum Reads 1 5 52 Disable Enable Code 93 Disable 5 53 Code 93 Length Con trol Variable Length 5 54 Code 93 Length 1 1 5 55 Code 93 Length 2 50 5 55 Code 93 Stitching Disable 5 56 Code 93 Minimum Reads 1 5 56 Disable Enable MSI Plessey Di...

Page 168: ... 63 Std 2 of 5 Check Digit Verification Disable 5 63 Std 2 of 5 Check Digit Transmit Enable 5 64 Std 2 of 5 Length Control Variable Length 5 65 Std 2 of 5 Length 1 8 5 66 Std 2 of 5 Length 2 50 5 66 Standard 2 of 5 Stitching Disable 5 67 Std 2 of 5 Minimum Reads 1 5 68 Disable Enable PDF417 Disable 5 69 PDF417 Length Control Variable Length 5 70 PDF417 Length 1 1 5 71 PDF417 Length 2 600 5 71 PDF4...

Page 169: ...A PC XT Scan Set 1 No No AT PS 2 25 286 PS 2 30 286 PS 2 50 50Z PS 2 60 70 80 90 95 Foreign ALT Mode Wedge B AT PS2 Scan Set 2 No No PS 2 25 and 30 Foreign ALT Mode Wedge C AT PS2 Scan Set 1 No No PC XT U S Mode Wedge D PC XT Scan Set 1 Yes No AT PS 2 25 286 PS 2 30 286 PS 2 50 50Z PS 2 60 70 80 90 95 U S Mode specific country support Wedge E AT PS2 Scan Set 2 Yes Yes PS 2 25 and 30 U S Mode Wedge...

Page 170: ...47h E0 12 DC2 LEFT arrow inner keypad 4Bh E0 13 DC3 DOWN arrow inner keypad 50h E0 14 DC4 UP arrow inner keypad 48h E0 ASCII hex ASCII code Key Scancode 00 NUL ALT right Make E0h 11h 01 SOH ALT right Break E0h F0h 11h 02 STX ALT left Make 11h 03 ETX ALT left Break F0h 11h 04 EOT CTRL left Make 14h 05 ENQ CTRL left Break F0h 14h 06 ACK CTRL right Make E0h 14h 07 BEL CTRL right Break E0h F0h 14h 08 ...

Page 171: ... CTRL left Break F0h 11h 06 ACK CTRL right Make 58h 07 BEL CTRL right Break F0h 58h 08 BS BS 66h 09 HT TAB right 0Dh 0A LF RIGHT arrow inner keypad 6Ah 0B VT TAB left 0Dh S 0C FF Enter inner keypad 79h 0D CR CR 5Ah 0E SO INSERT inner keypad 67h 0F SI PAGE UP inner keypad 6Fh 10 DLE PAGE DOWN inner keypad 6Dh 11 DC1 HOME inner keypad 6Eh 12 DC2 LEFT arrow inner keypad 61h 13 DC3 DOWN arrow inner ke...

Page 172: ... Enter Make Break 58h F0h 58h 08 BS BS 66h 09 HT TAB right 0Dh 0A LF RIGHT arrow inner keypad 6Ah 0B VT TAB left 0Dh S 0C FF CR FIELD EXIT Make only 5Ah F0h 5Ah 0D CR CR FIELD EXIT Make Break 5Ah 0E SO INSERT inner keypad 65h 0F SI FIELD 79h 10 DLE FIELD 7Ch 11 DC1 HOME inner keypad 62h 12 DC2 LEFT arrow inner keypad 61h 13 DC3 DOWN arrow inner keypad 60h 14 DC4 UP arrow inner keypad 63h 15 NAK F6...

Page 173: ...t Break C1h 08h BS BS 3Eh 09h HT TAB right 3Ch 0Ah LF RIGHT arrow inner keypad 4Dh 0Bh VT TAB left 3Ch S 0Ch FF Enter right keypad 60h 0Dh CR CR 3Bh 0Eh SO INSERT inner keypad 52h 0Fh SI PAGE UP inner keypad 49h 10h DLE PAGE DOWN inner keypad 51h 11h DC1 HOME inner keypad 4Ch 12h DC2 LEFT arrow inner keypad 4Bh 13h DC3 DOWN arrow inner keypad 4Ah 14h DC4 UP arrow inner keypad 4Eh 15h NAK F6 6Dh 16...

Page 174: ... TAB right 0Fh 0Ah LF RIGHT arrow inner keypad 3Ch 0Bh VT TAB left 0Fh S 0Ch FF DELETE 39h 0Dh CR CR 1Ch 0Eh SO INSERT inner keypad 38h 0Fh SI KATAKANA LOCK ON Make 72h 10h DLE KATAKANA LOCK OFF Break F2h 11h DC1 HOME inner keypad 3Eh 12h DC2 LEFT arrow inner keypad 3Bh 13h DC3 DOWN arrow inner keypad 3Dh 14h DC4 UP arrow inner keypad 3Ah 15h NAK F6 67h 16h SYN F1 62h 17h ETB F2 63h 18h CAN F3 64h...

Page 175: ...ch Support for more details COMMAND ASCII HEX COMMENT Enable Scanner E 0x45 Disable Scanner D 0x44 Reset Scanner R 0x52 Not On File Indication F 0x46 Long series of beeps Beep Good Read Tone B 0x42 Beeps if Good Read Beep is enabled Force Good Read Tone 0x01 Beeps regardless of beep setting Bel 0x07 Force Good Read Tone Identification request i 0x69 Returns long responsea a Call Tech Support for i...

Page 176: ...F 2 Magellan 1400i NOTES ...

Page 177: ...ct Reference Guide G 1 Chapter G Sample Symbols 0 1234567890 1234567890 Code 128 9 780330 290951 BC321 123456 9 123456 UPC A Code 128 Code 39 Code 93 Interleaved 2 of 5 EAN 13 Code 2 of 5 A13579B Codabar 0 5 ...

Page 178: ...G 2 Magellan 1400i Sample Symbols 01 00123456789012 RSS 14 0100123456789050 RSS Expanded ...

Page 179: ...3 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V W X Y Z _ 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F a b c d e f g h i j k l m n o p q r s t u v w x y z DEL 60 61 62 63 64 65 66 67 68 69 6A 6B 6...

Page 180: ...39 6859496 Japan Datalogic Scanning KK Shinagawa Tokyo Japan Telephone 81 0 3 3491 6761 Fax 81 0 3 3491 6656 Latin America Datalogic Scanning Inc Miami Florida USA Telephone 305 591 3222 Fax 305 591 3007 Spain and Portugal Datalogic Scanning Sarl Sucursal en España Madrid Spain Telephone 34 91 746 28 60 Fax 34 91 742 35 33 United Kingdom Datalogic Scanning LTD Watford England Telephone 44 0 1923 8...