Pin Number
NX-series Unit
NX-series Unit Terminal
Description
20 to 23
IOG
Ground
24
Connected to chassis for shielding
A circuit diagram is provided below for the digital outputs.
OUT0 to OUT7
In
te
rn
a
l ci
rcu
its
Sh
or
t-
ci
rcu
it
pr
ot
ec
tio
n
REG PWR 0 VDC
REG PWR 24 VDC
A circuit diagram is provided below for the analog outputs.
AMP
Analog circuit internal GND
REG PWR 0 VDC
Output V1+ to V4+
COMMS
The COMMS connector on the User Access Panel is reserved for future use.
INT LAN1
The INT LAN1 connector on the User Access Panel is reserved for future use.
INT LAN2
The INT LAN2 connector on the User Access Panel is reserved for future use.
USER LAN
The USER LAN connector on the User Access Panel is used to access the internally mounted NX102
unit. Use this connector to transfer user-defined programs to the NX102 unit for application-specific
functionality such as I/O control or ARCL command operations. This connector can also be used for
periodic updates to the safety control system issued by OMRON.
3 Installation
3-22
HD-1500 Platform User's Manual (I645)
Summary of Contents for HD-1500 Platform
Page 1: ...HD 1500 Platform User s Manual I645 E 03 ...
Page 6: ...Manual Information 4 HD 1500 Platform User s Manual I645 ...
Page 38: ...Revision History 36 HD 1500 Platform User s Manual I645 ...
Page 206: ...5 Troubleshooting 5 14 HD 1500 Platform User s Manual I645 ...
Page 236: ...6 Maintenance 6 30 HD 1500 Platform User s Manual I645 ...
Page 250: ...Appendices A 14 HD 1500 Platform User s Manual I645 ...
Page 251: ...I Index I 1 HD 1500 Platform User s Manual I645 I ...
Page 254: ...Index I 4 HD 1500 Platform User s Manual I645 ...
Page 255: ......