![background image](http://html1.mh-extra.com/html/omron/hd-1500-platform/hd-1500-platform_user-manual_743962229.webp)
1
Unlatch the skin and pull it away from the AMR so that you can disconnect the cable. Refer to
6-9-1 Removing and Replacing Skins
on page 6-18 for more information.
Move the skin to an adequate working area after detaching it from the AMR.
2
After the cable is disconnected, remove the skin completely.
3
Remove the four screws near the edge of electronics bay seal cover using a 7 mm nut driver.
This will allow the LED mount plate to be removed once unscrewed from the skin.
4
Remove the six nuts holding the LED mount plate to the side skin using a 7 mm nut driver.
5
Remove the four screws holding the diffuser plate to the LED mount plate using a 2.5 mm hex
wrench.
6
Carefully lift the electronics bay seal cover and then remove the LED mount plate completely to
expose the LED light assembly.
7
Disconnect the LED light electrical connector.
8
Remove the LED light by peeling away from the LED mount plate.
Take note of the LED light orientation before removing it. Installing the new LED light in the in-
correct orientation will cause the lighting patterns to display in reverse.
6 Maintenance
6-23
HD-1500 Platform User's Manual (I645)
6-9 Replacing Items
6
6-9-2
Light Disc LED Replacement Procedure
Summary of Contents for HD-1500 Platform
Page 1: ...HD 1500 Platform User s Manual I645 E 03 ...
Page 6: ...Manual Information 4 HD 1500 Platform User s Manual I645 ...
Page 38: ...Revision History 36 HD 1500 Platform User s Manual I645 ...
Page 206: ...5 Troubleshooting 5 14 HD 1500 Platform User s Manual I645 ...
Page 236: ...6 Maintenance 6 30 HD 1500 Platform User s Manual I645 ...
Page 250: ...Appendices A 14 HD 1500 Platform User s Manual I645 ...
Page 251: ...I Index I 1 HD 1500 Platform User s Manual I645 I ...
Page 254: ...Index I 4 HD 1500 Platform User s Manual I645 ...
Page 255: ......