3 - 23
3 Communications Data for CompoWay/F
E5@D Digital Temperature Controllers Communications Manual (H225)
3-
2 Stat
u
s 1 a
nd St
atu
s 2
3
z
Status 1 Details
Note1 “Spare” bits are always OFF.
2 When read in setup area 1, the status of the bits will be as follows:
*
When the control output ON time is less than 30 ms for a control period of 0.1 s or 0.2 s or when it is less
than 100 ms for any other control period, the bit is set to “1” and the heater current is held at the last current
value.
Bit position
Status
Bit Description
0
1
Status
(lower
word)
0
Heater overcurrent (CT1)
Not generated
Generated
1
Heater current hold (CT1)*
Update
Hold
2
A/D converter error
Not generated
Generated
3
HS alarm (CT1)
OFF
ON
4
Spare
OFF
---
5
Spare
OFF
---
6
Input error
Not generated
Generated
7
Spare
OFF
---
8
Control output (heating)
OFF
ON
9
Control output (cooling)
OFF
ON
10
HB (heater burnout) alarm (CT1)
OFF
ON
11
HB (heater burnout) alarm (CT2)
OFF
ON
12
Alarm 1
OFF
ON
13
Alarm 2
OFF
ON
14
Alarm 3
OFF
ON
15
Program end output
OFF
ON
Status
(upper
word)
16
Event input 1
OFF
ON
17
Event input 2
OFF
ON
18
Event input 3
OFF
ON
19
Event input 4
OFF
ON
20
Write mode
Backup mode
RAM write mode
21
Non-volatile memory
RAM = Non-volatile
memory
RAM
≠
Non-volatile
memory
22
Setup area
Setup area 0
Setup area 1
23
AT execute/cancel
AT canceled
AT execution in
progress
24
RUN/STOP
Run
Stop
25
Communications writing
OFF (disabled)
ON (enabled)
26
Auto/manual switch
Automatic mode
Manual mode
27
Program start
Reset
Start
28
Heater overcurrent (CT2)
Not generated
Generated
29
Heater current hold (CT2)
Update
Hold
30
Ambient temperature input error
Not generated
Generated
31
HS alarm (CT2)
OFF
ON
•
Overcurrent:
Last value held
•
A/D converter error:
Last value held
•
Input error:
Last value held
•
HB and HS outputs:
Cleared
•
Program end output:
Cleared
•
Current hold:
Last value held
•
Heating and cooling outputs:
Cleared
•
Alarm outputs:
Cleared
•
Ambient temperature input error:
Current value reflected
Summary of Contents for E5 D Series
Page 2: ......
Page 20: ...18 E5 D Digital Temperature Controllers Communications Manual H225 ...
Page 28: ...1 Communications Methods 1 8 E5 D Digital Temperature Controllers Communications Manual H225 ...
Page 205: ...I 1 E5 D Digital Temperature Controllers Communications Manual H225 I Index ...
Page 208: ...I 4 E5 D Digital Temperature Controllers Communications Manual H225 ...
Page 209: ......