1 Communications Methods
1 - 6
E5@D Digital Temperature Controllers Communications Manual (H225)
Before you carry out communications with the E5
@
D, set up the communications unit number, baud
rate, and other parameters by carrying out the following procedure. For details on operations other than
communications parameter setup, refer to the
E5
@
D Digital Temperature Controllers User's Manual
(Cat. No. H224) for the devices being used.
(1) Press the
O
Key for at least three seconds to move from the "operation level" to the
"initial setting level."
(2) Press the
O
Key for less than one second to move from the "initial setting level" to
the "communications setting level."
(3) Select the parameters as shown below by pressing the
M
Key.
(4) Use the
D
or
U
Keys to change the parameter set values.
*1
Displayed only when the Protocol Setting parameter is set to CompoWay/F.
*2
Displayed when the Protocol Setting parameter is set to CompoWay/F or Modbus.
1-1-7
Communications Parameter Setup
Protocol Setting
Communications Unit
No.
Communications
Baud Rate
Communications Data
Length
*1
Communications Stop
Bits
*1
Communications
Parity
*2
Send Data Wait Time
M
M
M
M
M
M
M
M
Write Mode
bps
9.6
len
7
sbit
2
prty
even
sdwt
20
psel
cwf
u-no
1
ramm
bkup
Summary of Contents for E5 D Series
Page 2: ......
Page 20: ...18 E5 D Digital Temperature Controllers Communications Manual H225 ...
Page 28: ...1 Communications Methods 1 8 E5 D Digital Temperature Controllers Communications Manual H225 ...
Page 205: ...I 1 E5 D Digital Temperature Controllers Communications Manual H225 I Index ...
Page 208: ...I 4 E5 D Digital Temperature Controllers Communications Manual H225 ...
Page 209: ......