6 - 89
6 Programless Communications
E5@D Digital Temperature Controllers Communications Manual (H225)
6
-11 Co
n
n
ectin
g t
o
Keye
nce KV-
series PLC
s
6
6-
11-4 E5
@
D Con
troller
Setup
Set up programless communications. Perform the procedure that is given in
6-4-4 E5
@
D Controller
Setup
.
The SP and RUN/STOP status of the E5
@
D Controllers will be changed to check operation. Make sure
that this will not create any problems in the controlled system.
z
Checking E5CD Monitor Values
(1) Place the PLC into Monitor Mode.
Select
Monitor Mode
from the Monitor/Simulator Menu on the KV STUDIO.
(2) The PLC Memory Dialog Box will be displayed.
Select
Batch Monitor Mode
from the Monitor/Simulator Menu on the KV STUDIO.
(3) Change the display format to make the values easier to check.
Select the first display format and change it to
Signed decimal 16 bits
.
(4) We will check the E5CD monitor values.
The area where monitor values are checked is called the upload area.
DM0 to DM14 is the upload area for the No. 0 Controller (E5CD), DM30 to DM44 is the
upload area for the No. 1 Controller, and DM60 to DM74 is the upload area for the No. 2
Controller.
With the default settings, the following parameters are set for the upload areas.
Check the values in the upload areas to see if they are the same as those that are given in
the following table. (It is not necessary to check address for which “---” is given in the Value
column.)
*
If the default settings are used and a sensor is not connected, the PV display on the E5CD will show an input
error (
s.err
) and the process value in the upload area will be 1320 (528 hex).
6-11-4 E5
@
D Controller Setup
6-11-5 Checking Operation
No.0
No.1
No.2
Parameter
Value
DM0
DM30
DM60
Response Flag (fixed)
0
DM1
DM31
DM61
Communications Status (fixed)
Alternates between 0 and 1.
DM2
DM32
DM62
Communications Monitor
Parameter
---
DM3
DM33
DM63
Status 1 (Upper Word)
---
DM4
DM34
DM64
Status 1 (Lower Word)
---
DM5
DM35
DM65
Status 2 (Upper Word)
---
DM6
DM36
DM66
Decimal Point Monitor
---
DM7
DM37
DM67
Process Value
Process Value
*
DM8
DM38
DM68
Internal Set Point
---
DM9
DM39
DM69
Heater Current 1 Value Monitor
---
DM10
DM40
DM70
MV Monitor (Heating)
---
DM11
DM41
DM71
Not used.
---
· · ·
· · ·
· · ·
· · ·
· · ·
DM13
DM43
DM73
Not used.
---
DM14
DM44
DM74
Do not use (reserved).
---
Summary of Contents for E5 D Series
Page 2: ......
Page 20: ...18 E5 D Digital Temperature Controllers Communications Manual H225 ...
Page 28: ...1 Communications Methods 1 8 E5 D Digital Temperature Controllers Communications Manual H225 ...
Page 205: ...I 1 E5 D Digital Temperature Controllers Communications Manual H225 I Index ...
Page 208: ...I 4 E5 D Digital Temperature Controllers Communications Manual H225 ...
Page 209: ......