6 - 7
6 Programless Communications
E5@D Digital Temperature Controllers Communications Manual (H225)
6-2 E5
@
D Set
u
p
6
6-
2-1 Pro
tocol Setting
6-2
E5
@
D Setup
The parameters that are used for programless communications are shown with a gray background in
the following diagram. These parameters will be displayed if you set the Protocol Setting parameter to
fins
,
mcp4
, or
fxp4
. (Some of the parameters are always displayed.) The parameters in the commu-
nications setting level are described first, followed by those in the adjustment level.
*
These parameters are displayed regardless of the setting of the Protocol Setting parameter.
Note: The Communications Data Length, Communications Stop Bits, and Communications Parity parameters in
the communications setting level are not displayed.
Set the Protocol Setting parameter to
fins
to connect to an OMRON PLC,
mcp4
to connect to a Mit-
subishi Q-series or L-series PLC,
fxp4
to connect to a Mitsubishi FX-series or Keyence KV-series
PLC, and
cmp
to use component communications. Refer to
6-1-5 Connectable PLCs
for lists of the
PLCs that can be connected.
Communications Setting Level
Display condition: None
6-2-1
Protocol Setting
Parameter name
Displayed characters
Setting range
Default
Protocol Setting
psel
cwf
: CompoWay/F
mod
: ModbusRTU
none
: Disabled (Do not select this setting.)
fins
: Host Link (FINS)
mcp4
: MC protocol (format 4)
fxp4
: Dedicated protocol (format 4)
cwf
Initial Setting Level
Operation Level
M
M
M
M
M
Protocol Setting
*
Communications
Unit No.
*
Communications
Baud Rate
*
Send Data Wait
Time
*
Highest
Communications
Unit No.
Area
Communications Setting Level
Power ON
M
M
M
M
M
First Address Upper
Word
First Address Lower
Word
Receive Data Wait
Time
Communications
Node Number
Upload Setting 1
M
M
M
M
Upload Setting 2
Download Setting 1
Download Setting 2
Copy
M
Adjustment Level
Display
AT Execute/Cancel
Communications
Writing
*
Work Bit 8 OFF
Delay
Adjustment Level
Communications
Monitor
Press
O
Key for
less than 1 s.
Press
O
Key for
at least 3 s.
Press
O
Key for
at least 1 s.
Press
O
Key for
less than 1 s.
M
M
M
M
M
l.adj
1234
at
off
cmwt
on
plcm
0
w8of
0
25
0
psel
fins
u-no
0
bps
57.6
sdwt
20
maxu
0
adrh
0
adrl
0
rwat
1000
unit
0
area
0
up02
2
dn01
31
dn02
61
copy
off
up01
1
in-t
5
M
Write Mode
*
ramm
bkup
Summary of Contents for E5 D Series
Page 2: ......
Page 20: ...18 E5 D Digital Temperature Controllers Communications Manual H225 ...
Page 28: ...1 Communications Methods 1 8 E5 D Digital Temperature Controllers Communications Manual H225 ...
Page 205: ...I 1 E5 D Digital Temperature Controllers Communications Manual H225 I Index ...
Page 208: ...I 4 E5 D Digital Temperature Controllers Communications Manual H225 ...
Page 209: ......