Configuring Your Workstation 4-35
(4) [RA]: Sets parameter for Read Ahead.
Parameter
Remarks
Off
Does not perform read ahead.
On *
Performs read ahead.
*
Recommended setting.
(5) [Span]: Sets Span.
Parameter
Remarks
SPAN=NO *
Does not set span.
SPAN=YES
Sets span.
*
Recommended setting.
When performing SPAN, create two or more sets of the same pack at pack creation, as
shown in the figure below.
SPANNING of RAID1
8.
When all settings are completed, select [Accept] and then press
Enter
.
The created virtual drive is displayed in the [Virtual Drive Configured] screen.
9.
Press
Esc
on [Virtual Drive Configured] screen to close it.
Select [Yes] on [Save Configuration?] screen to save the configuration.
10.
When the confirmation message shows that the configuration has been saved, press
Esc
to return to the TOP menu screen.
11.
On the TOP menu screen, select [Objects]
→
[Virtual Drive]
→
[View/Update
Parameters] to check virtual drive information.
12.
Press
Esc
to go back to TOP menu.
Select [Initialize] on the TOP menu screen.
13.
When the [Virtual Drives] screen appears, move the cursor to the virtual drive to be
initialized, and press
Space
.
The virtual drive is selected.
Summary of Contents for Express5800/53La
Page 1: ...NEC Express5800 53La User s Guide 1st Edition 11 2010 ONL 550_009_02_53La 100 99 1011 ...
Page 30: ...1 16 Notes on Using Your Workstation This page is intentionally left blank ...
Page 56: ...2 26 General Description This page is intentionally left blank ...
Page 120: ...4 48 Configuring Your Workstation This page is intentionally left blank ...
Page 252: ...A 2 Specifications This page is intentionally left blank ...
Page 256: ...B 4 Other Precautions This page is intentionally left blank ...
Page 311: ...Installing Windows XP E 23 3 Process Windows activation according to the following message ...