NovaScale R620 User Guide
7-37
If disks are mounted on PCI modules (IO modules), the status of both modules is
“
Simplex
”
while the
disks are mirrored. Temperature or voltage error occurring during disk mirroring will result in the
system to shut down.
Network drive is not displayed in the data viewer:
→
On Windows XP or the OS released after it, the drive connected to network is not displayed under the
file system tree in the data viewer of ESMPRO Manager.
Shutdown monitoring:
→
When performing shutdown monitoring, all shutdown processes are to be monitored. If there is an
application that performs shutdown without rebooting OS or turning off the power, set the timeout
value longer or disable the monitoring function.
The external clock of CPU is listed as
“
Unknown
”
:
In [CPU information] of Data Viewer
’
s system tree, the external clock is listed as
“
Unknown
”
.
[ft Server] tree appears on data viewer in an incorrect manner:
After the system starts up, the tree or the state of a Data Viewer may not be displayed correctly due to
high load of the system. In about 20 minutes after the system start-up, when a pop-up message which
prompts you to reconstruct a Data Viewer appears, click [OK]. The Data Viewer will be reconstructed
and the tree and the status will be displayed correctly.
The information on the floppy disk appears in an incorrect manner:
After switching on and off the power of the CPU/PCI module (CPU/IO module), the floppy disk drive
name of [I/O Device] on Data Viewer may be different from the name that is recognized by the OS.
(Example: drive name on Data Viewer:
“
A
”
drive name recognized by the OS
“
B
”
)
Check the floppy disk drive name on Explorer.
If you add or delete floppy disk drive connected with USB while the system is running, the drive
information under the [I/O Device] in the data viewer will be updated at the next system start-up.
When the Displayed BIOS Information is Incorrect
Additional information of BIOS which is displayed by clicking [ft] - [CPU Module] - a CPU module - [General] -
[BIOS Information] on a Data Viewer or by clicking a CPU module and clicking [BIOS Information] on Server
Maintenance Utility may not be displayed correctly. In such a case, display the BIOS information on a Data Viewer by
clicking [ESMMIB] - [BIOS].
The status of Ethernet board is displayed as an error:
If an Ethernet adapter is not used (not connected to cable), set it to
“
Disable
”
in [Network
Connections] from Control Panel. If an Ethernet adapter are about to disable has dual LAN settings
(AFT function), remove the dual LAN settings before disable it.
ESMPRO Agent does not work properly in the environment where Oracle products and ESMPRO
Agent coexist:
The installation of the Oracle products may change Start-up type of SNMP Service into
“
Manual
”
. If
so, change the setting back to
“
Automatic
”
and set up correctly according to the description of the
Oracle product.
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......